Abstract:Mixer chips have wide functionality, which is not always declared by the manufacturer. The purpose of the experimental study is to prove the possibility of implementing a frequency multiplier based on the mixer chip LTC5553. An experimental study of the LTC5553 chip in the mode of frequency multiplication was performed 2, 4 and 6 times. The second harmonic transmission coefficient is not less than minus 17.25 dB, for the fourth harmonic not less than minus 35 dB, for the sixth harmonic -not less than minus 42.… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.