Experimental investigation of the seismic performance of flexible pipes for seismically isolated buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…e isolation layer is set on the basement roof, and the podium and tower above the ground are isolated as a whole to form the first floor bottom base isolation scheme (Figure 4). e main advantages of this scheme are as follows: it can greatly reduce the seismic response of tower and podium, the concept and principle of isolation are clear, and the details of isolation structure are easy to handle, which is conducive to improving the structure layout and improving the building quality [16]. However, the whole chassis including the podium needs to be equipped with isolation bearings under each transfer column, resulting in a large number of isolation bearings, and a total of 148 isolation bearings need to be arranged, which has an impact on the economy of the scheme.…”
Section: Base Isolation Scheme Of the First Floormentioning
confidence: 99%
“…e isolation layer is set on the basement roof, and the podium and tower above the ground are isolated as a whole to form the first floor bottom base isolation scheme (Figure 4). e main advantages of this scheme are as follows: it can greatly reduce the seismic response of tower and podium, the concept and principle of isolation are clear, and the details of isolation structure are easy to handle, which is conducive to improving the structure layout and improving the building quality [16]. However, the whole chassis including the podium needs to be equipped with isolation bearings under each transfer column, resulting in a large number of isolation bearings, and a total of 148 isolation bearings need to be arranged, which has an impact on the economy of the scheme.…”
Section: Base Isolation Scheme Of the First Floormentioning
confidence: 99%
“…[6] Dong et al [7] compared the seismic resilience of fixed-base and base-isolated steel buildings. Shang et al [8] and Xie et al [9,10] investigated the seismic resilience of isolated RC frame buildings with an emphasis on flexible pipes, which are critical NSCs in the isolation system. Domenico and Ricciardi [11] conducted a seismicresilient design using base isolation and tuned mass damper.…”