1970
DOI: 10.1016/s0022-5347(17)61813-5
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Investigations of Bladder Regeneration Using Teflon-Felt as a Bladder Wall Substitute

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

1978
1978
2015
2015

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 56 publications
(10 citation statements)
references
References 25 publications
0
10
0
Order By: Relevance
“…The most commonly used materials in experimental studies and clinical trials are Teflon, silicon and collagen matrices (61). However, cell and tissue incompatibilities appear to be the major restrictions of these materials, leading to the development of other synthetic polymers, such as PLGA (62)(63)(64)(65). These materials were designed specifically to possess adequate structural and biological properties, which can be manipulated for optimal cell proliferation and differentiation (66).…”
Section: Naturally Derived Matricesmentioning
confidence: 99%
“…The most commonly used materials in experimental studies and clinical trials are Teflon, silicon and collagen matrices (61). However, cell and tissue incompatibilities appear to be the major restrictions of these materials, leading to the development of other synthetic polymers, such as PLGA (62)(63)(64)(65). These materials were designed specifically to possess adequate structural and biological properties, which can be manipulated for optimal cell proliferation and differentiation (66).…”
Section: Naturally Derived Matricesmentioning
confidence: 99%
“…This lipid membrane prevents adherence of other agents including bacteria and crystals. Alloplasts like the ones mentioned above can now be surface coated with PC [30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44]. Studies of fibrinogen and platelet binding have shown significant reductions in adsorption on the PC-coated alloplasts [30]as compared with non-PC-coated controls.…”
Section: Total Alloplastic Artificial Bladdermentioning
confidence: 99%
“…Porous alloplasts carry a high risk of urinary encrustation [35], and their use as intraurinary device should be avoided. However, silicone or polyurethane may be coated on their external surface with porous alloplasts that watertightly bind the device to autologous tissues and eliminate the ‘fibrous encapsulation’ that occurs with native polymers.…”
Section: Total Alloplastic Artificial Bladdermentioning
confidence: 99%
See 2 more Smart Citations