2010
DOI: 10.1107/s0907444909038360
|View full text |Cite
|
Sign up to set email alerts
|

Experimental phasing with SHELXC/D/E: combining chain tracing with density modification

Abstract: The programsSHELXC, SHELXDandSHELXEare designed to provide simple, robust and efficient experimental phasing of macromolecules by the SAD, MAD, SIR, SIRAS and RIP methods and are particularly suitable for use in automated structure-solution pipelines. This paper gives a general account of experimental phasing using these programs and describes the extension of iterative density modification in SHELXEby the inclusion of automated protein main-chain tracing. This gives a good indication as to whether the structu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
941
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 1,092 publications
(946 citation statements)
references
References 42 publications
4
941
0
1
Order By: Relevance
“…After performing a fluorescence scan, three data sets were collected from a single crystal at the peak, inflection, and low-energy remote wavelengths (Extended Data Table 2b). From the peak data set, the positions of 14 zinc ions (7 in each Pol I complex) were determined with SHELX C and D 53 . The occupancies calculated by SHELX were between 100% and 58% for the first 14 sites, followed by a drop to ,25% for additional peaks that were not considered.…”
Section: Research Article Methodsmentioning
confidence: 99%
“…After performing a fluorescence scan, three data sets were collected from a single crystal at the peak, inflection, and low-energy remote wavelengths (Extended Data Table 2b). From the peak data set, the positions of 14 zinc ions (7 in each Pol I complex) were determined with SHELX C and D 53 . The occupancies calculated by SHELX were between 100% and 58% for the first 14 sites, followed by a drop to ,25% for additional peaks that were not considered.…”
Section: Research Article Methodsmentioning
confidence: 99%
“…Initial automated heavy atom substructure determination, phasing, and density modification were done using autoSHARP (36). A total of 31 bromide sites were found by ShelxD (37) in the single monomer present in the asymmetric unit and used in the phasing process. BUCCANEER (38) was able to build an incomplete model.…”
Section: Methodsmentioning
confidence: 99%
“…Data were indexed, integrated, and scaled with the program HKL2000 (56). Phases were determined using the program SHELX (57). Refinement, density modification, and model building were done using the program package PHENIX (58).…”
Section: Methodsmentioning
confidence: 99%