Abstract:To improve the shear performance of assembly connections in precast RC shear wall structures, a novel polygon‐key assembly connection (PKA connection) was proposed. Shear tests were carried out to study the shear performance of the PKA connections, specimens' parameters considered in the tests consist of polygon‐key inclination angles, polygon‐key heights, and axial compression ratios. Shear capacity, stiffness, and failure modes of the PKA connections were investigated. Furthermore, theoretical analysis of th… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.