2009
DOI: 10.1016/j.expthermflusci.2009.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Experimental research on the thermal performance of converging slot holes with different divergence angles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(4 citation statements)
references
References 27 publications
0
4
0
Order By: Relevance
“…Detailed flow structures of console film cooling flow field were also investigated by Azzi and Jubran [17] and Yao et al [18] through numerical simulations. Liu et al [19,20] further investigated the effect of console geometry variants including exit-entry area ratio and divergence angle on the film cooling performance of the consoles. The investigations showed that properly changing the geometry parameters of the console could improve the film cooling performance.…”
Section: Introductionmentioning
confidence: 99%
“…Detailed flow structures of console film cooling flow field were also investigated by Azzi and Jubran [17] and Yao et al [18] through numerical simulations. Liu et al [19,20] further investigated the effect of console geometry variants including exit-entry area ratio and divergence angle on the film cooling performance of the consoles. The investigations showed that properly changing the geometry parameters of the console could improve the film cooling performance.…”
Section: Introductionmentioning
confidence: 99%
“…Azzi et al [14] and Yao et al [15][16][17] found that the anti-kidney vortices formed downstream of the console are the key factors to improve film cooling effectiveness. Liu et al [18][19] investigated the influence of the different divergence angles and area ratios of exit-entry on the film cooling performance of the console. The results show that adjusting the geometric parameters of console properly could make the film cooling effect improved.…”
Section: Introductionmentioning
confidence: 99%
“…This specific flow structure has excellent potential in the enhancement of film cooling, because it could suppress the normal penetration of cooling flow into the primary flow and prevent the lateral invasion of the primary flow into the film layer. Liu et al [21,22] experimentally studied the influence of console exit-entry area ratio and lateral expansion angle on the thermal and film cooling performances. They pointed out that the consoles with smaller area ratio of exit and entry have smaller discharge coefficient and larger film cooling effectiveness.…”
Section: Introductionmentioning