Experimental studies on effect of bonding the twisted tape with pins to the inner surface of the circular tube

Abstract: Heat transfer and friction factor characteristics are studied for water flowing through the tube in tube heat exchanger for two different configurations, namely,(1) twisted tape with pins and (2) twisted tape with pins bonded to the inner surface of the test section. Experiments are carried out for different twist pitch to the width of the twisted tape ratios (y/w) for both configurations. But very few research works have been done based on the mentioned heat transfer enhancement techniques. This paper present… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…The maximum increase in the heat-transfer rate and the coefficient of friction was about 4.2 and 110 times compared to a conventional tube for the investigated range. Selvam et al (2013) conducted experiments on different twisting steps along the width of the twisted tape, and the ratio (y/w is the twist coefficient) for the propeller. A variation of the Nusselt number with the Reynolds number for a pipe equipped with a propeller with three different ratios.…”
Section: Discussionmentioning
confidence: 99%
“…The maximum increase in the heat-transfer rate and the coefficient of friction was about 4.2 and 110 times compared to a conventional tube for the investigated range. Selvam et al (2013) conducted experiments on different twisting steps along the width of the twisted tape, and the ratio (y/w is the twist coefficient) for the propeller. A variation of the Nusselt number with the Reynolds number for a pipe equipped with a propeller with three different ratios.…”
Section: Discussionmentioning
confidence: 99%
“…Due to decrease in the area of flow there is increase in flow velocity and turbulence mixing, which results in increase in heat transfer coefficient and pressure drop. S.Selvam et al [2] performed Experimental investigations of heat transfer and friction factor characteristics of a circular tube fitted with full-length twisted tape with pins of different twist ratios have been studied in tube in tube heat exchangers for the turbulent flow of Re ranging between 10000 to 23 000. Author suggested that use of bonded twisted tape with pins in the tube in tube heat exchanger enhances the heat transfer with significant pressure drop.…”
Section: Literature Surveymentioning
confidence: 99%
“…S. Selvam et al [23] carried on experiments for different twist pitch to the width of the twisted tape ratios (y/w) for TTP and TTPB. The variation of Nusselt number with Reynolds number for the tube fitted with TTP of three different y/w ratios (3.33, 4.29, and 5.71).…”
Section: Mr Salimpour and S Yarmohammadimentioning