Experimental studies on impedance based fault location for long transmission lines

Abstract: In long transmission lines, the charging current caused by the shunt capacitance decreases the accuracy in impedance based fault location. To improve the accuracy of fault location, this paper presents a novel scheme, where two Digital Fault Recorders (DFRs) are installed in a line. They can send the transient data of the faults to the both ends of a line. To estimate the distance of a fault, impedance based fault location methods are applied with transient fault data of both ends protection relays and both DF… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
21
0
3

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(32 citation statements)
references
References 15 publications
0
21
0
3
Order By: Relevance
“…The concrete values of these parameters are shown in Appendix A. 24 The length of the line is 5 km. The unbalanced 3-phase power flow calculation was calculated by the multiphase harmonic load flow program developed by the UA power lab for the analysis of power flow, which can be used for both the harmonic and unbalance study programs.…”
Section: Sensitivity Analysis Of the Proposed Methods With Respect Tmentioning
confidence: 99%
See 1 more Smart Citation
“…The concrete values of these parameters are shown in Appendix A. 24 The length of the line is 5 km. The unbalanced 3-phase power flow calculation was calculated by the multiphase harmonic load flow program developed by the UA power lab for the analysis of power flow, which can be used for both the harmonic and unbalance study programs.…”
Section: Sensitivity Analysis Of the Proposed Methods With Respect Tmentioning
confidence: 99%
“…All mutual impedances are equal, and they are expressed as Z SM . The relationship between the POE 3-phase voltage and current can be derived based on the upstream network parameters as shown in Equation 24.…”
Section: Case 2: the Unbalance Is Totally From The Downstreammentioning
confidence: 99%
“…The equivalent impedance between terminals and fault types are required. Fault location algorithms that utilize two-terminal measurements are proposed in [10,11]. Fault location techniques that utilize traveling waves generated by faults are proposed in [12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…Currently travelling wave and impedance-based methods used for finding Open -circuit fault location. In Impedance bases method, phasor voltage and phasor current measured from either sides or single side of transmission line [6][7][8][9][10][11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%