2015
DOI: 10.1016/j.egypro.2015.02.158
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Study of a Novel PV/T- Air Composite Heat Pump Hot Water System

Abstract: Solar energy utilization and heat pump are common technologies of renewable energy utilization for solving the problem of energy crisis and environmental pollution in present. This paper proposed a novel PV/T-air composite heat pump hot water system. The system was comprised of independently developed flat plate solar PV/T collector based on micro-channel heat pipe array and air source heat pump, which were combined by a new composite evaporator. The performance of the system were experimentally studied COP of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…System Approach Location Results [14] BIPV/T-ASHP Simulation Toronto, Canada Seasonal COP could be increased from 2.7 to 3.5 [15] PVT-ASHP Simulation Shenyang, China Heating COP of the ASHP varied from 3.6 to 4.9 [16] PVT-ASHP Experimental Beijing, China System COP ranged from 1.33 to 6.07 [17] PVT-GSHP Simulation Stockholm, Sweden System SPF ranged from 1.8 to 3.4 [18] PVT-GSHP Simulation Seoul, South Korea System SPF of the System varied from 4 to 10 [19] PVT-GSHP Simulation Amman, Jordan Heating COP of the ASHP varied from 4.6 to 6.2 [20] GAHX-PVT-AWHP Simulation Incheon, South Korea Average system COP was 2.87…”
Section: Refmentioning
confidence: 99%
“…System Approach Location Results [14] BIPV/T-ASHP Simulation Toronto, Canada Seasonal COP could be increased from 2.7 to 3.5 [15] PVT-ASHP Simulation Shenyang, China Heating COP of the ASHP varied from 3.6 to 4.9 [16] PVT-ASHP Experimental Beijing, China System COP ranged from 1.33 to 6.07 [17] PVT-GSHP Simulation Stockholm, Sweden System SPF ranged from 1.8 to 3.4 [18] PVT-GSHP Simulation Seoul, South Korea System SPF of the System varied from 4 to 10 [19] PVT-GSHP Simulation Amman, Jordan Heating COP of the ASHP varied from 4.6 to 6.2 [20] GAHX-PVT-AWHP Simulation Incheon, South Korea Average system COP was 2.87…”
Section: Refmentioning
confidence: 99%
“…And most of the researches focused on the energetic performance. For example, Wang et al [88] built experiment of the PV/T-ASHP hot water system in laboratory and tested the system. The system was comprised of independently developed flat plate solar PV/T collector based on micro-channel heat pipe array and air source heat pump, which were combined by a new composite evaporator.…”
Section: Pv/t-ashp Systemmentioning
confidence: 99%
“…A novel model of using heat pump for water heating has been proposed, comprising a PV/T collector with micro heat pipe arrangement. In the meantime, this proposed study had solved the issue of air-based heat pump which frosted under cold climate season, by using an evaporator [34].…”
Section: Installations Of Pvt Systemsmentioning
confidence: 99%