2020
DOI: 10.1016/j.fusengdes.2020.112072
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of hypervapotron channel with square fin structure for divertor cooling by one-side, electric joule heating system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 7 publications
0
13
0
Order By: Relevance
“…The top surface of the copper chromium zirconium alloy (CuCrZr) heat sink was electrically insulated by spray a coating of 100μm-thick Al 2 O 3 ceramic layer, and a 400μm FeCrAl heating plate was pressed onto the top surface to enable one-sided heating. Detailed information on the loop and one-side electrical joule heating system can be found in previous studies [12,13].…”
Section: Experimental Methods 21 Experimental Facilitiesmentioning
confidence: 99%
“…The top surface of the copper chromium zirconium alloy (CuCrZr) heat sink was electrically insulated by spray a coating of 100μm-thick Al 2 O 3 ceramic layer, and a 400μm FeCrAl heating plate was pressed onto the top surface to enable one-sided heating. Detailed information on the loop and one-side electrical joule heating system can be found in previous studies [12,13].…”
Section: Experimental Methods 21 Experimental Facilitiesmentioning
confidence: 99%
“…Therefore, in this part, by cooling the amount of heat loaded in the test-section, the thermal steady state can be maintained in the closed loop. Further details on the selection of experimental equipment and design of the experimental loop can be found in our previous studies [23][24][25][26], and the experimental range of and the uncertainty of the measured variables in this study can be found in table 2.…”
Section: Experimental Methods 21 Experimental Loopmentioning
confidence: 99%
“…Current flow in the loop was prevented through the installation of di-electric union fittings at the front and rear ends of the channel, with extra precautions taken through the grounding the electric wire of the pump. Detailed information on the selection of experimental equipment and loop design process can be found in previous reports [8,10,18,20]. Table 1 summarizes the experimental ranges and uncertainties of the primary equipment.…”
Section: Test Loopmentioning
confidence: 99%
“…Additionally, an AlN plate with a very low HTC was installed on top of the FeCrAl heater to prevent heat loss over the channel. Detailed information on the heater development process and material selection can be found in a previous papers [10,20,23].…”
Section: One-side Joule Heating Assemblymentioning
confidence: 99%
See 1 more Smart Citation