2007
DOI: 10.1016/j.ijrefrig.2006.06.002
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of the refrigeration cycle performance for the R744/R290 mixtures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 57 publications
(18 citation statements)
references
References 3 publications
0
18
0
Order By: Relevance
“…Much research has been devoted to the alternative refrigerants HFC32(R32) (Dalkilic and Wongwises, 2010;Xu et al, 2013), HC290(R290) (Fernando et al, 2008a, b;Padalkar et al, 2014;Park and Jung, 2007) and the related mixtures (Bobbo et al, 2003;Coquelet et al, 2004;Dalkilic and Wongwises, 2010;Niu and Zhang, 2007;Tanaka and Higashi, 2007;Yu et al, 2010). R32 has an ODP of zero and a GWP of 675, and R290 has an ODP of zero and a GWP of 3.3 (Forster et al, 2007).…”
Section: Introductionmentioning
confidence: 99%
“…Much research has been devoted to the alternative refrigerants HFC32(R32) (Dalkilic and Wongwises, 2010;Xu et al, 2013), HC290(R290) (Fernando et al, 2008a, b;Padalkar et al, 2014;Park and Jung, 2007) and the related mixtures (Bobbo et al, 2003;Coquelet et al, 2004;Dalkilic and Wongwises, 2010;Niu and Zhang, 2007;Tanaka and Higashi, 2007;Yu et al, 2010). R32 has an ODP of zero and a GWP of 675, and R290 has an ODP of zero and a GWP of 3.3 (Forster et al, 2007).…”
Section: Introductionmentioning
confidence: 99%
“…To validate our model, we compare our results with the results obtained experimentally by Niu et al 15 and theoretically by Nicola et al 33 The model of Niu et al is a vapor compression cascade refrigeration system. It used R290 as highstage's refrigerant and the mixture co 2 /propane (71/29) as low-stage's refrigerant.…”
Section: Validation and Simulationmentioning
confidence: 75%
“…Nicola et al 14 analyzed the performance of cascade refrigeration cycle operated with a blend of carbon dioxide and HFC (R125, R41, R32, R23) as the low-stage and ammonia as the high-stage. They concluded that R744 blends can be considered as an attractive option for the low-stage in cascade system operating at 200 K. Ni et al 15 proposed an environment friendly new alternative refrigerant to R13 composed of R744/ R290 (71/29, mole fraction). Results showed that R744/R290 blends can be considered as a good substitute for R13 when the evaporator temperature is higher than 201 K. Kim et al 16 developed a fully instrumented air-conditioning system to evaluate the transcritical cycle of CO 2 and the subcritical cycle of CO 2 /propane mixture of 75/25 and 60/40 by the charged mass percentage.…”
Section: Introductionmentioning
confidence: 99%
“…[ Table 3] and propane can overcome the limitation of CO 2 triple point [26]. It can also be seen from Fig.9 that M A N U S C R I P T…”
Section: Effect Of Vapor Quality In Fhex (mentioning
confidence: 83%