2016
DOI: 10.1016/j.buildenv.2016.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on airflow characteristics of a square column attached ventilation mode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
4

Relationship

2
7

Authors

Journals

citations
Cited by 62 publications
(16 citation statements)
references
References 32 publications
0
16
0
Order By: Relevance
“…To be more specific, displacement ventilation seems to be the most promising for creating a better IAQ and an acceptable thermal comfort level indoors [25,269]. Displacement ventilation based on square column attachment has superior performance of ventilation efficiencies and thermal comforts compared to traditional mixing ventilations [270,271]. Meanwhile, considering air velocity, air temperature, age of air, and relative warmth index (RWI), Liu et al assessed air distributions by adopting three different air supply schemes (mixing ventilation, stratified air ventilation, and air curtain ventilation) for a subway platform and demonstrated that air curtain ventilation presented an appropriate velocity and temperature distribution [22].…”
Section: Mitigation Measuresmentioning
confidence: 99%
“…To be more specific, displacement ventilation seems to be the most promising for creating a better IAQ and an acceptable thermal comfort level indoors [25,269]. Displacement ventilation based on square column attachment has superior performance of ventilation efficiencies and thermal comforts compared to traditional mixing ventilations [270,271]. Meanwhile, considering air velocity, air temperature, age of air, and relative warmth index (RWI), Liu et al assessed air distributions by adopting three different air supply schemes (mixing ventilation, stratified air ventilation, and air curtain ventilation) for a subway platform and demonstrated that air curtain ventilation presented an appropriate velocity and temperature distribution [22].…”
Section: Mitigation Measuresmentioning
confidence: 99%
“…Taking the square column attached ventilation as an example, three regions can be divided including the column attached region, the primary floor attached region and the merged floor attached region (Figure 3(b)). 13 With an increase in the supply air velocity, the main body thickness of the attached supply air becomes thinner, which corresponds to a lower degree of entrainment between the supply air and the ambient air. There can be a great benefit to promote ventilation efficiency (Figure 3(c)).…”
Section: Performance Of Attachment Ventilationmentioning
confidence: 99%
“…Because of this, the experimental test was carried out under isothermal conditions. However, the main purpose of this experiment was to introduce the CAV mode and obtain some airflow characteristics for engineering design, where the isothermal condition was also useful [18].…”
Section: Experimentationmentioning
confidence: 99%
“…Furthermore, the CAV also has the potential to overcome the drawbacks of take-up effective occupied space when configured DV air diffusers. Consequently, this ventilation strategy is believed to combine the advantages of both the MV and DV systems [18].…”
Section: Introductionmentioning
confidence: 99%