2018
DOI: 10.1016/j.fuel.2018.07.049
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on burning behavior of crude oil pool fire in annular ice cavities

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 38 publications
(13 citation statements)
references
References 32 publications
0
13
0
Order By: Relevance
“…In addition, the variations of flame height with pressure of PMMA and PE present the similar law although the flame height of PMMA is higher than PE. Flame height for horizontal pool fire can be scaled with the dimensionless heat release rate, which is proportional to the burning rate for horizontal pool fire considering air entrainment and the fuel's combustion . According to the experimental results as shown in Figure , the burning rate of PMMA is larger than that of PE; thus, the flame height of PMMA is higher than that of PE.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the variations of flame height with pressure of PMMA and PE present the similar law although the flame height of PMMA is higher than PE. Flame height for horizontal pool fire can be scaled with the dimensionless heat release rate, which is proportional to the burning rate for horizontal pool fire considering air entrainment and the fuel's combustion . According to the experimental results as shown in Figure , the burning rate of PMMA is larger than that of PE; thus, the flame height of PMMA is higher than that of PE.…”
Section: Resultsmentioning
confidence: 99%
“…As shown in Figure 4 air entrainment and the fuel's combustion. 25 According to the experimental results as shown in Figure 8, the burning rate of PMMA is larger than that of PE; thus, the flame height of PMMA is higher than that of PE.…”
Section: Flame Heightmentioning
confidence: 89%
“…With the increase of tunnel mileage, the driving density of vehicles will also be increased, so the tunnel safety becomes increasingly serious. Fire is one of the disasters, which may occur in the tunnel, as the vehicles always carry a lot of solid, liquid, and gaseous combustibles . When a fire occurs in the tunnel, because of its long‐narrow structure, hot smoke will quickly spread throughout the tunnel, and it will be difficult to be discharged in time .…”
Section: Introductionmentioning
confidence: 99%
“…Fire is one of the disasters, which may occur in the tunnel, [9][10][11][12][13][14][15][16][17][18][19][20] as the vehicles always carry a lot of solid, liquid, and gaseous combustibles. [21][22][23] When a fire occurs in the tunnel, because of its long-narrow structure, hot smoke will quickly spread throughout the tunnel, and it will be difficult to be discharged in time. [24][25][26][27][28] The toxic gases produced by fire source will seriously affect the evacuation of stranded persons and rescue work of fire department.…”
Section: Introductionmentioning
confidence: 99%
“…Fires can cause traffic congestion and lead to serious casualties. [8][9][10][11] Many tunnel fire cases show that the toxic smoke is the main cause of casualties 12-14 ;thus, how to effectively control the smoke is an important issue for emergency ventilation and smoke exhaust in tunnel fires. [15][16][17][18] There are mainly two kinds of ventilation systems in tunnels, that is, natural ventilation and mechanical ventilation with jet fans.…”
mentioning
confidence: 99%