Experimental Study on the Influence of Air Conveyor System Parameters on Vibration of Glass Substrate
Yunjie Ma,
Bin Huang,
Zhi Xu
et al.
Abstract:In this paper, the method of experimental research is used to minimize the micro-vibration amplitude of 0.6 mm thick glass substrates in the air conveyor system. The optimal parameter combination of the small orifice throttling glass substrate air conveyor system is obtained as follows: orifice diameter 0.25 mm, orifice spacing 60 mm and air-film thickness 50 μm. Secondly, based on the orthogonal experimental data, the influence of the main parameters of the air conveyor system at the micro vibration of the gl… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.