2020
DOI: 10.1016/j.supflu.2019.104682
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on the mixing characteristics inside an inner preheating transpiring-wall reactor for supercritical water oxidation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…Simulation area was discretized through structural quadrilateral grids, of which total number was 1.5 Â 10. 5 Boundary layer was densified at the internal surface of the porous transpiring wall to improve calculation accuracy. The grid independence verification was conducted to eliminate the computational errors caused by grids.…”
Section: Physical Model and Boundary Conditionsmentioning
confidence: 99%
“…Simulation area was discretized through structural quadrilateral grids, of which total number was 1.5 Â 10. 5 Boundary layer was densified at the internal surface of the porous transpiring wall to improve calculation accuracy. The grid independence verification was conducted to eliminate the computational errors caused by grids.…”
Section: Physical Model and Boundary Conditionsmentioning
confidence: 99%
“…Given the inlet stream's conditions and flowrate, constraining outflows to satisfy experimental conditions as well as the energy balance, and assuming that light gases came out in the top stream and inerts came out in the bottom stream, the water flowrate distribution between the top and bottom could be derived, mass balances completed, and outlet streams completely determined. This approach is only strictly correct for thermodynamic equilibrium, and transfer dynamics or spatial distribution issues [36] may have detracted from its correctness, but considering the experimental residence times (20-30 s) and with steady-state operation energy analysis purposes, it can be considered acceptable.…”
Section: Supercritical Water Oxidation Reactormentioning
confidence: 99%
“…GT operating parameters were taken from the lowest range of CHP setups (3-7 MWe) in the U.S, EPA (Environmental Protection Agency) Catalogue of CHP Technology [36]. The specific values were: compression ratio = 30, air to fuel ratio (AFR) = 3.5, η s = 0.85 for the compressor and η s = 0.90 for the expander.…”
Section: Gas Turbine (Gt) and Combined Heat And Power (Chp)mentioning
confidence: 99%
“…2000), supercritical degrading refractory organic wastewater process performance (Zhang et al. 2020 c ), lithium battery nanoparticles production in a supercritical hydrothermal synthesis process (Hong et al. 2013), supercritical combustion performance and pollutant emissions (Cheng et al.…”
Section: Introductionmentioning
confidence: 99%