2021
DOI: 10.1016/j.ijrefrig.2021.05.032
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on the operating characteristics of a display refrigerator phasing out R134a to R1234yf

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(6 citation statements)
references
References 18 publications
1
5
0
Order By: Relevance
“…The pressure (P) -specific enthalpy (h) diagram obtained from the validation tests was given in Figure 11. Accordingly, it was seen that the actual P-h diagram overlapped with previous studies [36]. Thus, it was concluded that the experimental setup was reliable.…”
Section: Validation Of Test Resultssupporting
confidence: 69%
See 1 more Smart Citation
“…The pressure (P) -specific enthalpy (h) diagram obtained from the validation tests was given in Figure 11. Accordingly, it was seen that the actual P-h diagram overlapped with previous studies [36]. Thus, it was concluded that the experimental setup was reliable.…”
Section: Validation Of Test Resultssupporting
confidence: 69%
“…The tests were performed at approximately the same evaporation and condensation temperatures. To validate the study, the actual refrigeration cycle with R1234yf is presented as in previous studies [36]. The pressure (P) -specific enthalpy (h) diagram obtained from the validation tests was given in Figure 11.…”
Section: Validation Of Test Resultsmentioning
confidence: 99%
“…The optimal charging capacity of R1234yf is 92.2 g, which is about 7.8% lower than that of R134a, and the energy consumption slightly increases by 4% compared with R134a 10 . The average ambient temperature is 40°C, and the calculated EER values of R1234yf and R513A are 5% and 7.5% lower than those of R134a 11 . The results show that the capacities of R1234yf/R134a and R134a are similar in cooling and heating modes 12 .…”
Section: Introductionmentioning
confidence: 84%
“…10 The average ambient temperature is 40 C, and the calculated EER values of R1234yf and R513A are 5% and 7.5% lower than those of R134a. 11 The results show that the capacities of R1234yf/R134a and R134a are similar in cooling and heating modes. 12 The comparative experimental study between R134a and its low GWP alternative R1234yf/R134a in a domestic refrigerator was presented.…”
Section: Introductionmentioning
confidence: 84%
“…The latter with a strong link to "absorption cooling" from the yellow cluster. This cluster comprises a wide range of experimental studies focused on improving the efficiency [27][28][29] and reducing the cost [30,31] of vapor compression systems.…”
Section: Analysis Of Abstractmentioning
confidence: 99%