2012
DOI: 10.1093/eurheartj/ehs095
|View full text |Cite
|
Sign up to set email alerts
|

Expert review document part 2: methodology, terminology and clinical applications of optical coherence tomography for the assessment of interventional procedures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
279
0
3

Year Published

2013
2013
2017
2017

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 362 publications
(284 citation statements)
references
References 56 publications
2
279
0
3
Order By: Relevance
“…When PCI with stenting was performed, OCT was used to assess the final stent result including for stent malapposition, defined as a strut/wall distance greater than the thickness of the strut (including polymer if any) 22,23 , significant intra-stent thrombotic protrusion (intraluminal tissue protrusion forming an arch between the stent struts 22,23 , considered moderate when less than and significant when more than 500 µm thick) or proximal/distal edge dissection (upstream or downstream: edge dissection).…”
Section: Medical Management Protocolmentioning
confidence: 99%
“…When PCI with stenting was performed, OCT was used to assess the final stent result including for stent malapposition, defined as a strut/wall distance greater than the thickness of the strut (including polymer if any) 22,23 , significant intra-stent thrombotic protrusion (intraluminal tissue protrusion forming an arch between the stent struts 22,23 , considered moderate when less than and significant when more than 500 µm thick) or proximal/distal edge dissection (upstream or downstream: edge dissection).…”
Section: Medical Management Protocolmentioning
confidence: 99%
“…63) These studies suggest that OCT can identify patients at high risk in the future. and tissue protrusion 70,71) in higher frequency compared to IVUS. 72,73) OCT is capable of detecting smaller stent edge dissection (Fig.…”
Section: Evaluation Of Non-culprit Plaque Characteristicsmentioning
confidence: 97%
“…21 IVUS can also accurately identify calcium, but it is unable to quantify its thickness. 22 The raw signals appearing from the reflection of ultrasound waves present a color-coded structure of plaque characteristics. In the last years, IVUS was frequently used and validated.…”
Section: Intravascular Ultrasoundmentioning
confidence: 99%
“…The acquisition rate can be set up in a series between 5 and 40 mm/s. 22 The applied energies in OCT are low and do not cause damage at the level of structural or functional tissue. OCT can penetrate calcium deposits that are located superficially, but penetration through superficial necrotic lipid pools is known to be less than through fibrous tissue or through calcified tissue.…”
Section: Optical Coherence Tomographymentioning
confidence: 99%
See 1 more Smart Citation