2018
DOI: 10.17675/2305-6894-2018-7-1-3
|View full text |Cite
|
Sign up to set email alerts
|

Expired Podocip drug as potential corrosion inhibitor for carbon steel in acid chloride solution

Abstract: The application of expired drugs as corrosion inhibitors provides a cost effective and environmentally benign alternative to otherwise tedious and costly disposal/degradation process. In this context, we have investigated the use of expired Podocip (PCIP) drug as corrosion inhibitor for carbon steel in 1 M HCl by weight loss and electrochemical methods. Polarization curves revealed that the inhibiting action of the PCIP is mixed-type. The adsorption of PCIP on carbon steel surface obeys the Langmuir isotherm. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 27 publications
1
7
0
Order By: Relevance
“…For a corrosion inhibitor to be considered efficient, the change in the e corr value must range between < 85 mV and > 85 mV and represents either a mixed-type inhibitor or an anodic/cathodic-type inhibitor, respectively [49]. In the present study, the maximum changes in the e corr value are 242 mV for 0.5 % exudate and 320 mV for 0.9 %, proving that the cedar extract molecule behaves as an anodic/cathodic-type inhibitor; therefore, it can be said that the anodic and cathodic reactions that do not vary due to active metallic sites are unblocked [50].…”
Section: Probability Of Steel Corrosionsupporting
confidence: 50%
“…For a corrosion inhibitor to be considered efficient, the change in the e corr value must range between < 85 mV and > 85 mV and represents either a mixed-type inhibitor or an anodic/cathodic-type inhibitor, respectively [49]. In the present study, the maximum changes in the e corr value are 242 mV for 0.5 % exudate and 320 mV for 0.9 %, proving that the cedar extract molecule behaves as an anodic/cathodic-type inhibitor; therefore, it can be said that the anodic and cathodic reactions that do not vary due to active metallic sites are unblocked [50].…”
Section: Probability Of Steel Corrosionsupporting
confidence: 50%
“…Electrochemical studies are used to measure the corrosion resistance of metals and alloys in various media. [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] The corrosion resistance of 18K gold in aritificial saliva, in the absenc and presence of Gemer-2 has been evaluated by electrochemical studies such as polarization study and AC impedance spectra.…”
Section: Electrochemical Studiesmentioning
confidence: 99%
“…However, these techniques are often unsuitable when the metal is exposed to a corrosive medium for a long time. Therefore, the use of corrosion inhibitors is one of the most common methods applied for protecting metal or alloy surfaces in acidic environment [9][10][11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%