2009
DOI: 10.1109/tuffc.2009.1364
|View full text |Cite
|
Sign up to set email alerts
|

Exploitation of capacitive micromachined transducers for nonlinear ultrasound imaging

Abstract: Capacitive micromachined ultrasonic transducers (CMUTs) present advantages such as wide frequency bandwidth, which could be further developed for nonlinear imaging. However, the driving electrostatic force induces a nonlinear behavior of the CMUT, thus generating undesirable harmonic components in the generated acoustic signal. Consequently, the use of CMUT for harmonic imaging (with or without contrast agents) becomes challenging. This paper suggests 2 compensation approaches, linear and nonlinear methods, to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
37
0
2

Year Published

2010
2010
2018
2018

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 51 publications
(39 citation statements)
references
References 23 publications
0
37
0
2
Order By: Relevance
“…Indeed, upon certain excitation conditions (e.g., low frequency and high voltage), the acoustic wave emitted from the CMUT can be distorted by the presence of higher frequency components generated by the transducer. 34,35 Although this limitation is particularly deleterious for harmonic imaging, various approaches such as the use of predistorted waveforms, 34,36 the development of specific pulse schemes 35 or by the addition of a series impedance to the CMUT capacitance, 37 have been recently proposed to suppress the undesired harmonic components. Here, the ADV signal will not be affected by nonlinear distortion because it is received well below the excitation frequency.…”
Section: Discussionmentioning
confidence: 99%
“…Indeed, upon certain excitation conditions (e.g., low frequency and high voltage), the acoustic wave emitted from the CMUT can be distorted by the presence of higher frequency components generated by the transducer. 34,35 Although this limitation is particularly deleterious for harmonic imaging, various approaches such as the use of predistorted waveforms, 34,36 the development of specific pulse schemes 35 or by the addition of a series impedance to the CMUT capacitance, 37 have been recently proposed to suppress the undesired harmonic components. Here, the ADV signal will not be affected by nonlinear distortion because it is received well below the excitation frequency.…”
Section: Discussionmentioning
confidence: 99%
“…Tissue harmonic imaging is a widely used imaging mode [18][19][20][21][22]. The ultrasound system sends out bursts of ultrasound at the fundamental frequency.…”
Section: Thi Principle and Previous Methodsmentioning
confidence: 99%
“…Compared to traditional PZT transducers, CMUT is at a disadvantage in THI mode because of the nonlinear transmit property from its electrostatic actuation mechanism [19,20], where the actuation force (hence the generated acoustic pressure)…”
Section: Thi Principle and Previous Methodsmentioning
confidence: 99%
See 2 more Smart Citations