2022
DOI: 10.4293/jsls.2022.00033
|View full text |Cite
|
Sign up to set email alerts
|

Exploring Adverse Events and Utilization of Topical Hemostatic Agents in Surgery

Abstract: Background and Objectives: This retrospective study provides preliminary qualitative assessment of the adverse events (AEs), focusing on pelvic and abdominal AEs and patient outcomes reported for three hemostatic agents used in gynecologic surgery. Methods: Utilization rates for oxidized regenerated cellulose powder (ORC), polysaccharide powder (PSP), and fibrin sealant solution (FSS) were obtained from hospitals via the Premier Healthcare databases for all surgical pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…- Adhesions formation: although OC is designed to be absorbed over time, in some cases, it may not fully degrade, leading to the formation of adhesion between tissues and organs; when OC comes into contact with nearby tissues, it may cause them to adhere together during the healing process; these adhesions may cause complications such as nerve compression, pain and interference with normal tissue function ( 5 , 8 , 9 ).…”
Section: Issues Related With the Use Of Ocmentioning
confidence: 99%
“…- Adhesions formation: although OC is designed to be absorbed over time, in some cases, it may not fully degrade, leading to the formation of adhesion between tissues and organs; when OC comes into contact with nearby tissues, it may cause them to adhere together during the healing process; these adhesions may cause complications such as nerve compression, pain and interference with normal tissue function ( 5 , 8 , 9 ).…”
Section: Issues Related With the Use Of Ocmentioning
confidence: 99%
“…The Manufacturer and User Facility Device Experience (MAUDE) database in the United States is a prospectively maintained library of anonymously reported failures related to surgical devices 9 . This inventory of adverse events can serve to provide valuable learning lessons across a wide range of surgical disciplines 10 . While there are a number of studies examining findings relevant to urological surgery, to our knowledge, there are none dedicated to this category of instruments and accessories used so widely in endourology.…”
Section: Introductionmentioning
confidence: 99%
“… 9 This inventory of adverse events can serve to provide valuable learning lessons across a wide range of surgical disciplines. 10 While there are a number of studies examining findings relevant to urological surgery, to our knowledge, there are none dedicated to this category of instruments and accessories used so widely in endourology.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, there is a worry that some forms of fibrin sealants may have negative consequences, such as leaving deadly air pockets inside the body. Warnings have been issued by the Food and Drug Administration (FDA) in the USA regarding the development of potentially fatal air or gas emboli following the use of fibrin sealant aerosol sprays during surgery ( 11 ). The risks of employing sprays too closely to exposed tissue surfaces and at pressures higher than those advised by the makers have been made clear to users of the goods.…”
Section: Introductionmentioning
confidence: 99%