Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
BackgroundA quarter of patients who present to emergency departments (EDs) have difficult intravenous access (DIVA), making it challenging for clinicians to successfully place a peripheral intravenous catheter (PIVC). Some literature suggests that guidewire PIVC improves first‐insertion success rate.AimThe aim was to determine the clinical and cost‐effectiveness of a novel long PIVC (5.8 cm) with a retractable coiled guidewire (GW‐PIVC) for patients with DIVA, compared with standard care PIVCs.MethodsA pragmatic randomized controlled trial was conducted in two Australian EDs. Eligible participants were adults assessed as meeting DIVA criteria. Participants were randomized (1:1 ratio; stratified by hospital) to either GW‐PIVC (long) or standard care group (short or long PIVC). The use of ultrasound was discretionary in the standard care group and was recommended in the GW‐PIVC group due to the pragmatic design that was primarily testing the GW‐PIVC rather than the ultrasound use. Primary outcome was first‐insertion success and secondary outcomes included all‐cause device failure, patient and staff satisfaction, and cost‐effectiveness. The analysis was intention to treat.ResultsA total of 446 participants were randomized and 409 received PIVCs. The use of GW‐PIVC, compared with standard PIVC, had a lower first‐insertion success rate (68% vs. 77%, odds ratio [OR] 0.65, 95% confidence interval [CI] 0.43–0.99, p < 0.05). There was no difference in PIVC failure (134.0 per 1000 catheter days [GW‐PIVC] vs. 111.8 [standard PIVC] per 1000 catheter days, hazard ratio 1.18, 95% CI 0.72–1.95). Both participant (8/10 vs. 9/10, median difference [MD] −1.00, 95% CI −1.37 to −0.63) and clinician (8/10 vs. 10/10, MD −2.00, 95% CI −2.37 to −1.63) satisfaction was lower with GW‐PIVCs compared with standard PIVCs. More nurses inserted standard PIVCs than GW‐PIVCs (56.9% vs. 36.5%) and had less confidence in their ultrasound skills (28.0% vs. 46.6% self‐claimed as advanced/expert users). The cost per participant of GW‐PIVC insertions was 2.46 times greater than standard PIVC insertions ($AU80.24 vs. $AU32.57).ConclusionsGW‐PIVCs had significantly lower first‐insertion success and non–significantly higher all‐cause catheter failure. Additional training and device design familiar to clinicians are vital factors to enhance the likelihood of successful future implementation of GW‐PIVCs.
BackgroundA quarter of patients who present to emergency departments (EDs) have difficult intravenous access (DIVA), making it challenging for clinicians to successfully place a peripheral intravenous catheter (PIVC). Some literature suggests that guidewire PIVC improves first‐insertion success rate.AimThe aim was to determine the clinical and cost‐effectiveness of a novel long PIVC (5.8 cm) with a retractable coiled guidewire (GW‐PIVC) for patients with DIVA, compared with standard care PIVCs.MethodsA pragmatic randomized controlled trial was conducted in two Australian EDs. Eligible participants were adults assessed as meeting DIVA criteria. Participants were randomized (1:1 ratio; stratified by hospital) to either GW‐PIVC (long) or standard care group (short or long PIVC). The use of ultrasound was discretionary in the standard care group and was recommended in the GW‐PIVC group due to the pragmatic design that was primarily testing the GW‐PIVC rather than the ultrasound use. Primary outcome was first‐insertion success and secondary outcomes included all‐cause device failure, patient and staff satisfaction, and cost‐effectiveness. The analysis was intention to treat.ResultsA total of 446 participants were randomized and 409 received PIVCs. The use of GW‐PIVC, compared with standard PIVC, had a lower first‐insertion success rate (68% vs. 77%, odds ratio [OR] 0.65, 95% confidence interval [CI] 0.43–0.99, p < 0.05). There was no difference in PIVC failure (134.0 per 1000 catheter days [GW‐PIVC] vs. 111.8 [standard PIVC] per 1000 catheter days, hazard ratio 1.18, 95% CI 0.72–1.95). Both participant (8/10 vs. 9/10, median difference [MD] −1.00, 95% CI −1.37 to −0.63) and clinician (8/10 vs. 10/10, MD −2.00, 95% CI −2.37 to −1.63) satisfaction was lower with GW‐PIVCs compared with standard PIVCs. More nurses inserted standard PIVCs than GW‐PIVCs (56.9% vs. 36.5%) and had less confidence in their ultrasound skills (28.0% vs. 46.6% self‐claimed as advanced/expert users). The cost per participant of GW‐PIVC insertions was 2.46 times greater than standard PIVC insertions ($AU80.24 vs. $AU32.57).ConclusionsGW‐PIVCs had significantly lower first‐insertion success and non–significantly higher all‐cause catheter failure. Additional training and device design familiar to clinicians are vital factors to enhance the likelihood of successful future implementation of GW‐PIVCs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.