1991
DOI: 10.1080/08916159108946424
|View full text |Cite
|
Sign up to set email alerts
|

Exprimental Study on Effects of a Single Porous-Type Roughness Element in a Parallel-Plate Duct

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

1995
1995
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…To solve the second problem, there have been several experimental investigations, which focused on eliminating or alleviating the LHTAs in the rear corners of attached solid ribs. Ichimiya et al [7] experimentally investigated a single porous rib in a parallel plate duct. Yamada and Osaka [8] studied the effects of the aspect ratio and the open-area ratio of a porous plate on the heat transfer characteristics.…”
Section: Introductionmentioning
confidence: 99%
“…To solve the second problem, there have been several experimental investigations, which focused on eliminating or alleviating the LHTAs in the rear corners of attached solid ribs. Ichimiya et al [7] experimentally investigated a single porous rib in a parallel plate duct. Yamada and Osaka [8] studied the effects of the aspect ratio and the open-area ratio of a porous plate on the heat transfer characteristics.…”
Section: Introductionmentioning
confidence: 99%
“…Similarly, the studies investigated on porous rib type roughness show better heat transfer enhancement over smooth wall duct. 112 Pentagonal ribs as compared with the square ribs reported lower pressure drop and high heat transfer in the downstream position of the ribs, avoiding the creation of local hot spots just behind the rib. 98 Table 13 presents the details of performance enhancement techniques in terms of artificial roughness, range of temperature and pressure drop, and optimum flow, and operating geometrical parameters.…”
Section: Porosity Of Bed = 96%mentioning
confidence: 96%
“…Artificial roughness of various forms and geometrical shapes investigated by different researchers is reported in the literature. The use of rib roughness in numerous shapes and geometries, such as square, 88,90,[103][104][105] triangular, 92,95,106,107 rectangular, 106,107 inclined, 93 V-shaped, 89,108 W-shaped, 94 discrete, 93,94,109 chamfered, 88 wedge shaped, 107 arc shaped, 97,106,110,111 L shaped, 96 U shaped, 91 porous rib type roughness, 112 and pentagonal ribs 98 result a better performance compared to conventional-type solar air collector. Many of the investigators reported considerable enhancement in heat transfer with less penalty of friction by the application of…”
Section: Ribs and Groovesmentioning
confidence: 99%
“…Further inclined separate ribs resulted in 10% to 20% surge in heat transfer. Ichimiya et al [10] used spongy type roughness on absorber plate and concluded that this type of roughness delivered greater thermal enactment as compared to the solid rib type roughness. Han and Zhang [11] used parallel and V-shaped staggered discrete ribs on absorber plate and concluded these discrete ribs at an angle of 60° resulted in surge in heat transfer.…”
Section: B Literature Reviewmentioning
confidence: 99%