2019
DOI: 10.1021/acschemneuro.9b00145
|View full text |Cite
|
Sign up to set email alerts
|

Extended (10-Day) Real-Time Monitoring by Dexamethasone-Enhanced Microdialysis in the Injured Rat Cortex

Abstract: Intracerebral microdialysis has proven useful for chemical monitoring in patients following traumatic brain injury. Recent studies in animals, however, have documented that insertion of microdialysis probes into brain tissues initiates a foreign-body response. Within a few days after probe insertion, the foreign body response impedes the use of microdialysis to monitor the K + and glucose transients associated with spreading depolarization, a potential mechanism for secondary brain injury. Herein, we show that… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

6
2

Authors

Journals

citations
Cited by 12 publications
(26 citation statements)
references
References 70 publications
7
19
0
Order By: Relevance
“…We also observed a second post-CCI phenomenon consisting of a slow, progressive decline of dialysate glucose from basal concentrations to levels below the detection limit ( Robbins et al, 2019 ). Once this occurred, glucose concentrations did not return to detectable levels.…”
Section: Applicationsmentioning
confidence: 86%
See 2 more Smart Citations
“…We also observed a second post-CCI phenomenon consisting of a slow, progressive decline of dialysate glucose from basal concentrations to levels below the detection limit ( Robbins et al, 2019 ). Once this occurred, glucose concentrations did not return to detectable levels.…”
Section: Applicationsmentioning
confidence: 86%
“…Our most recent study was to investigate whether the microdialysis with DEX is translatable to the monitoring of spontaneous SD in rats after controlled cortical impact (CCI), a widely studied rodent model of TBI ( Dixon et al, 1987 ; Wagner et al, 2005 ; Xiong et al, 2013 ). Microdialysis probes were placed 1 or 3 mm away from the CCI site expecting that the secondary injury would spread over time into the penumbra ( Robbins et al, 2019 ). But this did not happen.…”
Section: Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recent advances in anti-inflammatory drug delivery through the perfusate [ 228 , 229 , 230 ] and ultrasmall microfabricated nano-probe development [ 219 ] have improved the tissue/probe interface, resulting in longer-lasting in vivo measurements. By perfusing the anti-inflammatory corticosteroid dexamethasone through the microdialysis probe, glucose levels in TBI model rats have been continuously monitored for upwards of 10 days without glial barrier formation [ 231 ].…”
Section: Alternative Methodsmentioning
confidence: 99%
“…Concentric style microdialysis probes were fabricated as previously described (Nesbitt et al, 2015;Varner et al, 2016;Robbins et al, 2019). Briefly, the probes were constructed in-house using hollow fiber membranes (18 kDa molecular weight cutoff, Spectra/Por RC, Spectrum, Rancho Dominguez, CA, United States) with a 280 µm OD, cut to a length of 1.5 mm.…”
Section: Microdialysis Probes and Proceduresmentioning
confidence: 99%