2015
DOI: 10.1016/j.memsci.2015.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Extended flue gas trials with a membrane-based pilot plant at a one-ton-per-day carbon capture rate

Abstract: a b s t r a c tA membrane-based pilot plant for carbon dioxide capture from the flue gas of a coal-fired power plant has been installed and operated at the National Carbon Capture Center in Wilsonville, Alabama, USA. The membrane system is sized to treat flue gas containing one ton per day of carbon dioxide. Stable operations for three extended runs conducted over a period of two years have been achieved with both pulverized coal and simulated natural gas flue gas. Carbon capture rates up to and over 90% were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
43
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 104 publications
(49 citation statements)
references
References 11 publications
2
43
0
Order By: Relevance
“…Ionic-liquid-functionalized graphene oxide in Pebax 1657 900 45 [18] Polaris 1000-2000 50-60 [19] Ionic liquid in polyimide 24 40 [20] Polymer/zeolite Y-composite 745 25 [21] Pebax 342 32 [22] Pebax/PEG DME 500 a) 940 30 [22] Pebax+zeolite layer 1420 10 [22] a) PEG DME=poly(ethylene glycol) dimethyl ether. Figure 2.…”
Section: Gas Permeation Experimentsmentioning
confidence: 99%
“…Ionic-liquid-functionalized graphene oxide in Pebax 1657 900 45 [18] Polaris 1000-2000 50-60 [19] Ionic liquid in polyimide 24 40 [20] Polymer/zeolite Y-composite 745 25 [21] Pebax 342 32 [22] Pebax/PEG DME 500 a) 940 30 [22] Pebax+zeolite layer 1420 10 [22] a) PEG DME=poly(ethylene glycol) dimethyl ether. Figure 2.…”
Section: Gas Permeation Experimentsmentioning
confidence: 99%
“…11768 | RSC Adv., 2016,6,[11763][11764][11765][11766][11767][11768][11769][11770][11771][11772] This journal is © The Royal Society of Chemistry 2016 and end groups into the Pebax® matrix can be clearly seen in Fig. 4, where the solubility and permeability coefficients of CO 2 as well as the CO 2 /N 2 selectivity are plotted against the PEO content in the system.…”
Section: Three-component Systemmentioning
confidence: 99%
“…5 Polymeric membranes based on poly(ethylene oxide) (PEO) have come to larger pilot scale production and are tested at several industrial sites for performance and stability in the environment of natural gas or coal red power plants ue gas streams. 6,7 The permeance and selectivity of developed PEO membranes lead to effective extraction of CO 2 from the ue gas while the modelling of separation process economy shows that membrane separation systems are competitive to other considered methods of CCS. 8 The selectivity of the developed membranes has reached the limit dened by the ideal selectivity of PEO based materials used for formation of the selective layer.…”
Section: Introductionmentioning
confidence: 99%
“…Two possible types of membranes are considered. The Polaris polymeric membrane developed by MTR [13] is believed to be at an advanced stage of development and testing [14] and is referred to as the reference membrane in several studies [15]. The Fixed Site Carrier (FSC) membrane was developed by NTNU [16] and has been tested at Norcem Brevik cement plant [17].…”
Section: Chain Design Alternativesmentioning
confidence: 99%