2002
DOI: 10.1007/s00216-002-1547-9
|View full text |Cite
|
Sign up to set email alerts
|

Extended traceability of pH: an evaluation of the role of Pitzer's equations

Abstract: The 2002 IUPAC recommendation on pH (provisional) has taken its own philosophy to provide a basis for comparable and traceable assignment of a value, from a measurement, to the quantity pH. Whereas the substituted 1983 IUPAC recommendation relied heavily on precisely prescribed experimental techniques and procedures, the current recommendation defines a hierarchical relationship between references for comparison (primary and secondary standards) and objective criteria on the comparison of measurements with the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 40 publications
0
6
0
Order By: Relevance
“…For example, Pitzer and Mayorga used mainly osmotic coefficient data from Robinson and Stokes to evaluate their parameters; Kim and Frederick obtained Pitzer parameters from smoothed osmotic coefficient data evaluated by Hamer and Wu and other authorities. As Meinrath has pointed out, non-normal distributions of residuals arise when preprocessed and smoothed experimental data are used to fit Pitzer equations. Moreover, the largest deviations from a normal distribution are found in β (1) , probably because this parameter depends strongly on osmotic coefficient data at low concentrations where the experimental uncertainty is usually largest.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, Pitzer and Mayorga used mainly osmotic coefficient data from Robinson and Stokes to evaluate their parameters; Kim and Frederick obtained Pitzer parameters from smoothed osmotic coefficient data evaluated by Hamer and Wu and other authorities. As Meinrath has pointed out, non-normal distributions of residuals arise when preprocessed and smoothed experimental data are used to fit Pitzer equations. Moreover, the largest deviations from a normal distribution are found in β (1) , probably because this parameter depends strongly on osmotic coefficient data at low concentrations where the experimental uncertainty is usually largest.…”
Section: Methodsmentioning
confidence: 99%
“…As Meinrath 31 has pointed out, non-normal distributions of residuals arise when preprocessed and smoothed experimental data are used to fit Pitzer equations. Moreover, the largest deviations from a normal distribution are found 31 in β (1) , probably because this parameter depends strongly on osmotic coefficient data at low concentrations where the experimental uncertainty is usually largest. It is reasonable to expect that the systematic bias arising in such cases will be reduced when the regressed data are obtained from diverse sources.…”
Section: ' Methodsmentioning
confidence: 99%
“…Given the real uncertainties in solubility measurements (Hefter, 2013;Hefter and Tomkins, 2003) it is completely unsatisfactory to assess the quality of a model in such a self-referencing manner. Meinrath and colleagues (Meinrath, 2002;Spitzer et al, 2011) claim, with good justification, that many mixing interactions in electrolyte solutions are not statistically significant. While some researchers contest this view, there can be little doubt that the experimental uncertainties are considerably greater than are commonly assumed.…”
Section: Sensitivity Of Pitzer Functionsmentioning
confidence: 99%
“…13 In fact, there has been some discussion in the literature regarding whether all values of θ and ψ for univalentunivalent electrolyte mixtures should actually be set to zero, with all calculated nonzero values simply representing noise in experimental data. 23 Equation 4 is a matrix formulation for the exchangerphase model in the general multicomponent case. 10,14,15 Here, species 0 is the solvent, and summation over dummy index Q includes all exchanging species as well as the solvent.…”
Section: Outline Of the Proposed Modelmentioning
confidence: 99%
“…This has been shown to have only a minor impact on the accuracy of activity coefficients calculated at the moderate concentrations used in this study . In fact, there has been some discussion in the literature regarding whether all values of θ and ψ for univalent−univalent electrolyte mixtures should actually be set to zero, with all calculated nonzero values simply representing noise in experimental data 2 Single Electrolyte Pitzer Model Parameters M X Ca 2+ Cl - 0.3159 a 1.614 a −0.00017 a SO 4 2- 0.2000 b 3.7762 b NO 3 - 0.2108 a 1.409 a −0.01007 a Na + Cl - 0.0765 a 0.2664 a 0.00127 a SO 4 2- 0.019575 a 1.113 a 0.00249 a NO 3 - 0.0068 a 0.1783 a −0.00072 a H + Cl - 0.1775 a 0.2945 a 0.00080 a SO 4 2- 0.2103 a 0.4711 a −0.00237 b NO 3 - 0.1168 a 0.3456 a −0.00539 a K + Cl - 0.04835 a 0.2122 a −0.00084 a Mg 2+ Cl - 0.3524 a 1.6815 a 0.002596 a a Ref .…”
Section: Outline Of the Proposed Modelmentioning
confidence: 99%