2016
DOI: 10.1002/jcla.22101
|View full text |Cite
|
Sign up to set email alerts
|

Extent of agreement between the body fluid model of Sysmex XN-20 and the manual microscopy method

Abstract: Due to the Sysmex XN-20 BF model's imperfect agreement with manual microscopy and its weak diagnostic accuracy for malignant diseases, the current evidence does not support replacing manual microscopy with this model in clinical practice.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(18 citation statements)
references
References 10 publications
5
13
0
Order By: Relevance
“…The XN‐BF module uses fluorescent flow cytometry with hydrodynamic focusing for generating total count (and classification) of RBC, WBC (XN‐WBC‐BF), and TC (XN‐TC‐BF) in BF samples. Briefly, a total volume of 88 µL is used for each BF sample . In the BF‐mode, the combination of laser side scatter (SSC), forward scatter (FSC), and fluorescence analysis (SFL) allows classifying nucleated cells, which are clustered in the WDF‐scattergram according to their complexity ( x ‐axis), size ( z ‐axis), and nucleic acid content ( y ‐axis).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The XN‐BF module uses fluorescent flow cytometry with hydrodynamic focusing for generating total count (and classification) of RBC, WBC (XN‐WBC‐BF), and TC (XN‐TC‐BF) in BF samples. Briefly, a total volume of 88 µL is used for each BF sample . In the BF‐mode, the combination of laser side scatter (SSC), forward scatter (FSC), and fluorescence analysis (SFL) allows classifying nucleated cells, which are clustered in the WDF‐scattergram according to their complexity ( x ‐axis), size ( z ‐axis), and nucleic acid content ( y ‐axis).…”
Section: Methodsmentioning
confidence: 99%
“…Cell counting and classification in body fluids (BFs; ascitic [AF], pleural [PF], synovial [SF], and cerebrospinal [CSF]) has become very popular in recent times due to enhanced availability of new commercial instrumentation . Carried out using suitable analyzers, automated cell count can now be regarded as a useful screening, since is adequately precise, may substantially reduce the turnaround time (TAT), is available 24 hours a day, and allows better standardization of the analytical process …”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations