2004
DOI: 10.1023/b:fire.0000039161.18616.86
|View full text |Cite
|
Sign up to set email alerts
|

Extinguishment of Cooking Oil Fires by Water Mist Fire Suppression Systems

Abstract: /npsi/ctrl?lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?lang=fr Access and use of this website and the material on it are subject to the Terms and Conditions set forth at http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=en NRC Publications Archive Archives des publications du CNRCThis publication could be one of several versions: author's original, accepted manuscript or the publisher's version. / La version de cette publication peut être l'une des suivantes : la version prépubli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0

Year Published

2005
2005
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(25 citation statements)
references
References 13 publications
0
25
0
Order By: Relevance
“…Although there were some temperature increase during the initial period of mist introduction, however in general the fires can be extinguish in a relatively short period of time. In addition, according to the literature the spray characteristics of individual nozzle, as well as multi nozzle arrangements, which are represented by spray coverage area, fluxs of water mist, and spray momentum are also important factors for extinguishing cooking oil fires [1][2][3][4]10]. Water mist coverage must be large enough to cover the entire oil surface and extinguish the whole flames over the oil surface at once, otherwise the flames will not be extinguished.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Although there were some temperature increase during the initial period of mist introduction, however in general the fires can be extinguish in a relatively short period of time. In addition, according to the literature the spray characteristics of individual nozzle, as well as multi nozzle arrangements, which are represented by spray coverage area, fluxs of water mist, and spray momentum are also important factors for extinguishing cooking oil fires [1][2][3][4]10]. Water mist coverage must be large enough to cover the entire oil surface and extinguish the whole flames over the oil surface at once, otherwise the flames will not be extinguished.…”
Section: Resultsmentioning
confidence: 99%
“…Nearly all accidental fire in hotels, restaurants, and fast food outlets start in kitchens, and the majority of these involve cooking oil [1]. Usually the average burning rates of cooking oils are higher than those of other hydrocarbon oils, and cooking oil fires (K class fire) are more difficult to extinguish than other liquid fires [2,3].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Water mist that consists of small water droplets (D v99 < 1000 µm) has been used to successfully extinguish various types of fires [3][4][5] as well as cooking oil fires in a commercial deep fat fryer without causing significant fire flare-up and re-ignition [6]. However, no research on usage of fine water mist against large cooking oil fires associated with the industrial oil cookers has been reported.…”
Section: Introductionmentioning
confidence: 99%