2018
DOI: 10.3906/elk-1703-84
|View full text |Cite
|
Sign up to set email alerts
|

Extra high voltage transmission line operation simulation using the actual corona-loss characteristics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 7 publications
0
5
0
Order By: Relevance
“…At the same time, the active resistance linearly depends on the temperature of the wires, the overheating of which depends on the current flowing through them. In addition, in previously published works [19][20][21] it is shown that corona losses depend on stresses in the power of 4-10. In addition, there is a reactive effect of the corona [20].…”
Section: Case Studymentioning
confidence: 94%
See 1 more Smart Citation
“…At the same time, the active resistance linearly depends on the temperature of the wires, the overheating of which depends on the current flowing through them. In addition, in previously published works [19][20][21] it is shown that corona losses depend on stresses in the power of 4-10. In addition, there is a reactive effect of the corona [20].…”
Section: Case Studymentioning
confidence: 94%
“…In addition, in previously published works [19][20][21] it is shown that corona losses depend on stresses in the power of 4-10. In addition, there is a reactive effect of the corona [20]. Therefore, when using the objective function COR(V,W) as components, the weighting factors were taken equal to zero at the correlation coefficients between: R0 and 1 2 + 2 2 , G0 and 1 2 + 2 2 , B0 and 1 2 + 2 2 .…”
Section: Case Studymentioning
confidence: 94%
“…This shows the air parameters, for example, temperature, pressure, wind speed, dampness, and so on., have the huge impact in the age of particles in the region of the HVDC transmission lines. Enock Chambile, et.al [2] reviewed a study on the direct non-generation greenhouse gas emissions in the construction and operation of the national electrical power transmission and distribution (T and D) system was conducted in order to understand its impact on climate change. The results revealed that the impact of the distance of T and D lines to the greenhouse gas emissions, due to vegetation removal, is insignificant.…”
Section: Related Workmentioning
confidence: 99%
“…Corona is solely a startling related to the sum of the lines of transmission. underneath express things, the electrical subject (close by) shut vitalized channels and fixings may develop to some degree electric supercharged discharge or corona that triggers the broad of air build up to ask ionized , or fitness minor controlled electrical rate exchange [2] [10]. Utility workplaces expect to lessen the measure of corona mishaps in light-weight of reality that the low degrees of change (sound) that outcome, corona may be a charged centrality setbacks, and in ludicrous events, it will hurt the sections of the structure as time goes on.…”
Section: Introductionmentioning
confidence: 99%
“…Recent PLC now offers high-speed data transmission and also economical as it makes use of the communication system already present and the cost mainly associated is only with the terminal equipment. More about this subject has been found in references [3][4][5][6]. Analog PLC (aPLC) is commonly used for transmission of voice and low data rate.…”
Section: Introductionmentioning
confidence: 99%