2015
DOI: 10.1155/2015/516826
|View full text |Cite
|
Sign up to set email alerts
|

Extraction of Heart Rate Variability from Smartphone Photoplethysmograms

Abstract: Heart rate variability (HRV) is a useful clinical tool for autonomic function assessment and cardiovascular diseases diagnosis. It is traditionally calculated from a dedicated medical electrocardiograph (ECG). In this paper, we demonstrate that HRV can also be extracted from photoplethysmograms (PPG) obtained by the camera of a smartphone. Sixteen HRV parameters, including time-domain, frequency-domain, and nonlinear parameters, were calculated from PPG captured by a smartphone for 30 healthy subjects and were… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

9
101
3
3

Year Published

2017
2017
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 135 publications
(116 citation statements)
references
References 37 publications
9
101
3
3
Order By: Relevance
“…All these requirements can be satisfied using a widely accessible tool called a smartphone like an iPhone 6. There were similar developments in the past, using other types of smartphones [12, 13, 20], but the device and implementation only permitted a low-frequency PPG measurement. The PPG measurement was compared to ECG statistics in that literature, and there was found to be a good correspondence between the HRV (heart rate variability) and PRV parameters.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…All these requirements can be satisfied using a widely accessible tool called a smartphone like an iPhone 6. There were similar developments in the past, using other types of smartphones [12, 13, 20], but the device and implementation only permitted a low-frequency PPG measurement. The PPG measurement was compared to ECG statistics in that literature, and there was found to be a good correspondence between the HRV (heart rate variability) and PRV parameters.…”
Section: Methodsmentioning
confidence: 99%
“…The iPhone 6 smartphone supports a 240-frame-per-second (FPS) video recording, the so-called “Slow-mo” video, and based on this feature, our plan was to develop a PPG measurement application with a sampling rate of 240 Hz. Another goal of this study was to compare our PRV measurements with those HRV parameters computed from the gold standard ECG signals and also to investigate our comparison results among other experiment results like those of [12, 13, 21]. Because different comparison methodologies were used in different research studies, we collected many of the HRV feature computation and comparison methods for the purpose of a thorough investigation.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…11 A new technique has also been practiced as replacement for traditionally calculated HVR from dedicated medical Electrocardiograph (ECG) 2 . It offers low-cost, ease-of-use in and outside the hospital.…”
Section: Resultsmentioning
confidence: 99%
“…2017, 9(3S), 858-886 860 muscle through the electrodes placing on specific human anatomical i.e. chests, legs, and arms [11]. Usually ECG test services only provided in certain health facilities because ECG machines are extremely bulky and expensive [12][13].…”
mentioning