Fabrication and Characterization of a Wrist Wearable Cuffless Pulsimeter by Using the Hall Effect Device

Abstract: A wrist wearable cuffless pulsimeter with a portable and small size apparatus using Hall effect is fabricated. The analysis of the pulse wave measured by the testing product of pulsimeter is done to measure the pulse rate and blood pressure. The blood pressure obtained by the puslimeter is compared with the practical values measured by electronic or mercury liquid blood pressure meters. The detail analysis of a pulse wave measured by a wrist wearable cuffless pulsimeter detecting the changes of the magnetic fi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…Latex rubber surrounds the contact skin surface of the wrist. Contacted cylinder permanent magnet with skin of radial artery is able to move easily by vibration of pulse [1,3].…”
Section: Experimental Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Latex rubber surrounds the contact skin surface of the wrist. Contacted cylinder permanent magnet with skin of radial artery is able to move easily by vibration of pulse [1,3].…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Magnetic sensor of Hall device is used A1395 type by Allegro Company that has highly sensitive and linear characteristic in strength of magnetic field. Within V CC input voltage has 10 mV/G sensitivity and let 0.1~3.2 V in the linear characteristic strength of magnetic field when apply to V CC /2 V of polarity [3,4].…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The permanent magnet is placed at the center of the elastic rubber and fixed with an epoxy adhesive. The latex rubber, placed in the “Chawn” position, is evenly extended from the center of the cylindrical magnet above the radial artery, covering the skin surface of the wrist [3–5]. The distance between the Hall effect device and permanent magnet is approximately 2.5 mm.…”
Section: Acquisition Of the Pulse Wave Using The Clip-type Pulsimetermentioning
confidence: 99%
“…U-health-care is important, not only as a new growth industry for the next generation, but also as a primary means of reducing medical expenses, especially in those countries where medical expenses have been on a continuous and steep rise, owing to an increasing elderly population [1]. Thus, U-health-care development research of a wearable medical device for bio-signals to measure the pulse wave velocity (PWV) and the spatial pulse wave velocity (SPWV) is required [2,3]. Here the SPWV slower than the PWV is the different bio-signal measuring the compliance or the tension level of blood vessels in the circulatory system.…”
Section: Introductionmentioning
confidence: 99%