“…Itta et al preferred to dry PPO/PVP and CMS membrane films at room temperature for one day [52] as well as Tseng et al [53] who dried PI or PEI/CMS MMMs also at room tem-perature. Another team of researchers used room temperature for drying the Matrimid®/ CMS MMM followed by vacuum oven drying at 100°C overnight for removal of the complete solvent [54].…”
Section: Drying Of Mmmsmentioning
confidence: 99%
See 1 more Smart Citation
“…Itta et al preferred to dry PPO/PVP and CMS membrane films at room temperature for one day [52] as well as Tseng et al [53] who dried PI or PEI/CMS MMMs also at room tem-perature. Another team of researchers used room temperature for drying the Matrimid®/ CMS MMM followed by vacuum oven drying at 100°C overnight for removal of the complete solvent [54].…”
Section: Drying Of Mmmsmentioning
confidence: 99%
“…They adopted three methods for drying the cast film: (i) at room temperature for one day, (ii) under atmospheric pressure with nitrogen atmosphere at 60°C -80°C for almost 10 h, (C) under partial vacuum with nitrogen circulation at 60°C -80°C for 8-10 h. Methods (a) and (b) were also carried out in quenching and annealing processes [37]. Itta et al preferred to dry PPO/PVP and CMS membrane films at room temperature for one day [52] as well as Tseng et al [53] who dried PI or PEI/CMS MMMs also at room tem-perature. Another team of researchers used room temperature for drying the Matrimid®/ CMS MMM followed by vacuum oven drying at 100°C overnight for removal of the complete solvent [54].…”
Section: Drying Of Mmmsmentioning
confidence: 99%
“…CMS membranes have been widely studied for application in air separation (O 2 /N 2 ), natural gas purification (CO 2 /CH 4 and N 2 /CH 4 ), CO 2 capture (CO 2 /N 2 ) and hydrogen recovery (H 2 /N 2 and H 2 /CH 4 ) [67,73,74]. However, few studies focused on H 2 /CO 2 separation.…”
Section: Carbon-based Membranesmentioning
confidence: 99%
“…The concept of polymer blends was first proposed by Ozaki et al [5]. Since then, a lot of similar efforts were reported such as polyimide/polyvinylpyrrolidone (PI/PVP) [2], phenol formaldehyde novolac resin polyethylene glycol (PFNR/PEG) [6], polyetherimide (PEI)/PVP [7][8][9], poly(p-phenylene oxide (PPO)/PVP [10], polybenzimidazole (PBI)/PI [11], and PI/PEG [12].…”