2018
DOI: 10.1016/j.talanta.2018.02.053
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of a novel enzymatic electrochemical biosensor for determination of tyrosine in some food samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
26
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 65 publications
(26 citation statements)
references
References 40 publications
0
26
0
Order By: Relevance
“…21,22 Different kinds of methods have been developed for the detection of Tyr such as HPLC, 23 capillary electrophoresis 24 and others. [25][26][27] All of LD, PA and Tyr are commonly used drugs in PD treatment. Especially, Tyr and LD have quite similar chemical structures and physiological functions.…”
Section: Introductionmentioning
confidence: 99%
“…21,22 Different kinds of methods have been developed for the detection of Tyr such as HPLC, 23 capillary electrophoresis 24 and others. [25][26][27] All of LD, PA and Tyr are commonly used drugs in PD treatment. Especially, Tyr and LD have quite similar chemical structures and physiological functions.…”
Section: Introductionmentioning
confidence: 99%
“…MATLAB can be linked with electrochemistry by the chemometricians and those electrochemists who are familiar with MATLAB-based chemometrical approaches. In electroanalytical projects, the sensor is usually modified with different materials to enhance the selectivity and sensitivity of the developed method [91][92][93][94][95][96][97][98][99][100][101][102][103] [104][105][106].The double layer charging current, which is generated with the change of potential on the working electrode surface, causes interference with the accurate measurement of the faradaic current and restricts the detection limit [107,108]. Since the analytical signal is usually generated by changing the potential in most electrochemical techniques, it is inevitable to include the charging current in the measured signal of an electroanalytical system.…”
Section: Casting a Look On Applications Of Matlab In Electrochemistrymentioning
confidence: 99%
“…Generally, after developing a new analytical method and validating its performance for the analysis of synthetic samples, its performance is compared with a reference method to verify its capability for the analysis of real samples. 52 Then, the newly developed analytical method could be suggested as a reliable method for routine analyses. Regarding this important step, we have also applied HPLC analysis of the cheese, egg and yogurt as real samples towards tyrosine determination and its results are presented in Table 3.…”
Section: Application Of the Modified Sensor To Real Samplesmentioning
confidence: 99%