2018
DOI: 10.1016/j.porgcoat.2017.11.006
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of hybrid coating material of polypropylene itaconate containing MOF-5 for CO2 capture

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 28 publications
(14 citation statements)
references
References 35 publications
0
14
0
Order By: Relevance
“…The adsorption of CO 2 gas was conducted according to the procedure described in [32]. The adsorption of CO 2 gas was conducted in a chamber with dimensions of 8 × 3 × 3 cm containing 0.1 g of adsorbent.…”
Section: Adsorption Of Comentioning
confidence: 99%
See 1 more Smart Citation
“…The adsorption of CO 2 gas was conducted according to the procedure described in [32]. The adsorption of CO 2 gas was conducted in a chamber with dimensions of 8 × 3 × 3 cm containing 0.1 g of adsorbent.…”
Section: Adsorption Of Comentioning
confidence: 99%
“…The standardization of the 0.00001 M NaOH solution was done with HCl standard solution. Calculation of the amount of adsorbed CO 2 was carried out following Equations (1)-(3) [32].…”
Section: Adsorption Of Comentioning
confidence: 99%
“…CO 2 adsorption was measured using the volumetric method according to a literature procedure [22,23] based on the acidimetric titration principle using NaOH. CO 2 gas was flowed to the sample through a flow meter at 50 mL/ min within 10 minutes at gas pressure of 2 bars.…”
Section: Co 2 Adsorption Tests On Hkust-1 Anz and Anz@hkust-1mentioning
confidence: 99%
“…The resulting carbonate salt was then titrated with HCl solution. In our previous work [23], phenolphthalein indicator was added into the carbonate solution followed by titration using HCl solution; then continued by addition of methyl orange indicator and again titrated with HCl solution. The required HCl titration volumes in the first and second stages were recorded.…”
Section: Co 2 Adsorption Tests On Hkust-1 Anz and Anz@hkust-1mentioning
confidence: 99%
“…These unique properties include adjustable pore size, internal surface areas, enormous porosity [43], regularity, rigidity/flexibility, and versatile structures [44]. These exceptional and unique properties attracted the interest for MOFs utilization in applications such as high capacity adsorbents [45,46,47,48,49], organic contaminants removal [50,51], environmental protection [52], heavy metals removal [53,54,55], H 2 storage [56,57,58,59,60] and purification [61], CO 2 adsorption [62,63] and capture [64,65,66,67,68,69,70], drug delivery [71,72,73,74,75,76,77,78], gas/liquid separation [79,80,81,82], membrane fuel cell [83], organic solvent nanofiltration [84,85,86,87] and storage media [88,89,90,91].…”
Section: Introductionmentioning
confidence: 99%