2017
DOI: 10.1016/j.carbpol.2017.04.020
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of Sustained-release CA-PU Coaxial Electrospun Fiber Membranes for Plant Grafting Application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(13 citation statements)
references
References 21 publications
0
13
0
Order By: Relevance
“…Nowadays, the pollutions in the water environment have become the global issue, which cause severe damage to people's health . Numerous research attentions have been addressed on the detection and removal of water pollutants.…”
Section: Resultsmentioning
confidence: 99%
“…Nowadays, the pollutions in the water environment have become the global issue, which cause severe damage to people's health . Numerous research attentions have been addressed on the detection and removal of water pollutants.…”
Section: Resultsmentioning
confidence: 99%
“…The peaks at 1221 cm −1 was corresponded to the stretching vibration of the C-N bonds. The bands at 1163 cm −1 and 1068 cm −1 represented the stretching vibration of the C-O-C groups [38,39]. In addition, there were no characteristic peaks at 1687 cm −1 and 1071 cm −1 which demonstrated that there were no residues of DMF and THF in the PU electrospun nanofibrous membrane.…”
Section: Chemical Characterization and Wettability Of As-prepared Memmentioning
confidence: 94%
“…The band around 1715 cm −1 was the characteristic peak of acetone, which can be attributed to the stretching vibration peak of the C=O group [35]. The peaks at 1050 cm −1 , 1232 cm −1 , 1369 cm −1 , and 1743 cm −1 of the CA membrane spectra can be assigned to the stretching vibrational peak of the C-O skeleton in ether group, stretching vibration of C-O-C bond, stretching vibration peak of C-CH 3 , and the stretching vibration of the C=O group, respectively [36][37][38]. Moreover, there were no characteristic peaks at 1687 cm −1 and 1715 cm −1 , indicating that there was no DMF and acetone solvent residues in the as-prepared CA electrospun nanofibrous membrane.…”
Section: Chemical Characterization and Wettability Of As-prepared Memmentioning
confidence: 97%
“…The hydrophilicity of cellulose acetate and hydrophobicity of coaxial polyurethane caused the loading of cargo drug in the latter due to the poor affinity of the drug with water. Notably, the encapsulated drug displayed two-stage release kinetics from the cellulose acetate-polyurethane coaxial electrospun fibers [110].…”
Section: Polysaccharide-based Contrast Agentmentioning
confidence: 99%