2013
DOI: 10.2494/photopolymer.26.533
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of the Plasma-Chemical Indicator and It’s Application

Abstract: In order to confirm the plasma processing effect at a required point by visual observation, the plasma-chemical indicator (PCI) was fabricated. In this research, the effects of NC and PA on discoloration properties of PCI was examined, since the color of prepared printing ink was fairly affected by the kind of binder. Viscosity effects of these binders on the sensitivity of PCI were also investigated. As an Application of PCI, the 3D mapping was created by the color difference E*ab obtained by 15 min of H O p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
3
1
1

Relationship

3
2

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 1 publication
0
9
0
Order By: Relevance
“…The color of PCI shifted toward green when the PCI made contact with the radicals such as ・OH, ・O and ・O 2 -. Whereas it is shifted toward red when the PCI made contact with O 2 ( 1  g ) [7,8]. The reactor is equipped with a 8.8-L bell-jar made of stainless steel in which parallel disk-electrodes are set.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The color of PCI shifted toward green when the PCI made contact with the radicals such as ・OH, ・O and ・O 2 -. Whereas it is shifted toward red when the PCI made contact with O 2 ( 1  g ) [7,8]. The reactor is equipped with a 8.8-L bell-jar made of stainless steel in which parallel disk-electrodes are set.…”
Section: Methodsmentioning
confidence: 99%
“…On the other hand, the resultant color of red in 100 Pa for O 2 plasma is explained by the ease of decomposing of green pigment in PCI against the action of O 2 ( 1  g ) [7,8]. As shown in Figure 8, the color of PCI after H 2 O 2 -O 2 plasma irradiation start is shifting in the green direction of -a, and it turns out that the time which showed the clearest green is 3 minutes after the start of plasma irradiation.…”
Section: Plasmamentioning
confidence: 99%
See 2 more Smart Citations
“…In a previous report [1,2], the sensitivity of PCI was distinguishable to 30% H 2 O 2 and O 2 plasma was fabricated by screen printing on a PET sheet using printing ink prepared on the bases of composition of ordinary gravure ink in which two different colorants, red azo-dye (Az-R) and green phthalocyanine pigment (Ph-G) and nitro cellulose (NC) and polyamide (PA) resins as binder were used. When the PCI was exposed to H 2 O 2 and H 2 O plasma, the color continuously shifted from the purple of control PCI toward dull light green and light bluish green respectively during 15 minutes of processing time with the action of •OH.…”
Section: Introductionmentioning
confidence: 99%