2020
DOI: 10.1016/j.epsr.2020.106600
|View full text |Cite
|
Sign up to set email alerts
|

Facilitating emission reduction using the dynamic line switching and rating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…A more flexible model incorporating OTS with DTR is presented in [99], where the authors instead of using real time ratings for DTR, assumed a predetermined increased capacity i.e., 10% of the normal ratings. The combination of OTS with DTR in reducing carbon dioxide emissions is presented in [100]. In addition to the constraints on the system dispatch and transmission constraints, Numerical results proved effective in reducing CO2 emissions.…”
Section: A Ots With Dynamic Thermal Ratingmentioning
confidence: 99%
“…A more flexible model incorporating OTS with DTR is presented in [99], where the authors instead of using real time ratings for DTR, assumed a predetermined increased capacity i.e., 10% of the normal ratings. The combination of OTS with DTR in reducing carbon dioxide emissions is presented in [100]. In addition to the constraints on the system dispatch and transmission constraints, Numerical results proved effective in reducing CO2 emissions.…”
Section: A Ots With Dynamic Thermal Ratingmentioning
confidence: 99%
“…The constraints (10) represents that the flow demand of each sink node takes value one and the flow demand of the singlesource node is set as 11) and ( 12) are arc capacity constraints, which represent that maximum flow on arcs cannot exceed the flow provided by the single-source node. In the other word, constraints (11) and (12) ensure that y l is zero when z l = 0 and 0 ≤ y l ≤ ( ∑ i∈Ω V v i ) when z l = 1.…”
Section: Srd-ots Modelmentioning
confidence: 99%
“…Recently, OTS has been proposed as a new method in mitigation of emergency states [3][4][5][6], economic dispatch [7][8][9][10] and system security enhancement [11,12]. In [3], a DC-OTS model was established by incorporating the DC power flow equations for handling with the congestion management, which is solved by a mixed integer programming (MIP) algorithm.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Luna et al [75] analyzed an EMS in an MG integrated with a grid-connected BESS that applies mixed-integer linear programming (MILP) to minimize the operating costs and improve the self-consumption strategy. Jabarnejad et al [76] developed an MILP approach to ensure an optimal power flow and to reduce the electricity generation costs and GHG emissions. Sarabi et al [77] proposed linear programming (LP) to minimize the annual energy invoice of railway station parking using plug-in electric vehicles (EV).…”
Section: Minimize the Costmentioning
confidence: 99%