1989
DOI: 10.1016/s0021-9673(01)84300-4
|View full text |Cite
|
Sign up to set email alerts
|

Factors affecting free zone electrophoresis and isoelectric focusing in capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
56
0

Year Published

1993
1993
2008
2008

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 255 publications
(57 citation statements)
references
References 11 publications
1
56
0
Order By: Relevance
“…Although in the past, reports have described CE systems that are based on different polymeric separation media in regard to sizing accuracy and resolution (Cohen et al 1988;Chin and Colburn 1989;Zhu 1989;Heiger et al 1990;Bocek and Chrambach 1991;Sudor et al 1991;Grossman 1992), we describe a novel linear polyacrylamide-derived com-mercially available polymer system specifically developed for high-resolution and high-precision fragment analysis on the ABI 310 Genetic Analyzer. An early version of this separation system, GeneScan polymer (GSP), was shown to be useful for identifying mobility abnormalities in double-stranded bent DNA (Wenz 1994).…”
mentioning
confidence: 99%
“…Although in the past, reports have described CE systems that are based on different polymeric separation media in regard to sizing accuracy and resolution (Cohen et al 1988;Chin and Colburn 1989;Zhu 1989;Heiger et al 1990;Bocek and Chrambach 1991;Sudor et al 1991;Grossman 1992), we describe a novel linear polyacrylamide-derived com-mercially available polymer system specifically developed for high-resolution and high-precision fragment analysis on the ABI 310 Genetic Analyzer. An early version of this separation system, GeneScan polymer (GSP), was shown to be useful for identifying mobility abnormalities in double-stranded bent DNA (Wenz 1994).…”
mentioning
confidence: 99%
“…Protein separations involving 0.03% hydroxypropylmethyl cellulose (HPMC) at pH 2.0 showed separation of the phosphorylated and non-phosphorylated as well as the acetylated and non-acetyl variants of Histone HI (86,87 kb when run at low voltages with good success (91,92,66). Lower voltages may be required when larger fragments are separated due to trapping of the DNA fragments in the polymer network (11).…”
Section: (84)mentioning
confidence: 99%
“…Much work has been applied to capillary electrophoresis (CE) to develop more sophisticated analytical systems for SBPS. For example, Zhu et al 3 adopted an entangled polymer, poly(ethylene glycol) (PEG), as a substite of a crosslinked sieving polymer such as poly(acrylamide) (PAA). It was reported that 7 proteins (14.2 -205 kDa) were separated within 12 min and also successive runs for 50 times were possible.…”
Section: Introductionmentioning
confidence: 99%