Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
No abstract
No abstract
Background Aging is a risk factor for falls, frailty, and disability. The utility of wearables to screen for physical performance and frailty at the population level is an emerging research area. To date, there is a limited number of devices that can measure frailty and physical performance simultaneously. Objective The aim of this study is to evaluate the accuracy and validity of a continuous digital monitoring wearable device incorporating gait mechanics and heart rate recovery measurements for detecting frailty, poor physical performance, and falls risk in older adults at risk of falls. Methods This is a substudy of 156 community-dwelling older adults ≥60 years old with falls or near falls in the past 12 months who were recruited for a fall prevention intervention study. Of the original participants, 22 participants agreed to wear wearables on their ankles. An interview questionnaire involving demographics, cognition, frailty (FRAIL), and physical function questions as well as the Falls Risk for Older People in the Community (FROP-Com) was administered. Physical performance comprised gait speed, timed up and go (TUG), and the Short Physical Performance Battery (SPPB) test. A gait analyzer was used to measure gait mechanics and steps (FRAIL-functional: fatigue, resistance, and aerobic), and a heart rate analyzer was used to measure heart rate recovery (FRAIL-nonfunctional: weight loss and chronic illness). Results The participants’ mean age was 74.6 years. Of the 22 participants, 9 (41%) were robust, 10 (46%) were prefrail, and 3 (14%) were frail. In addition, 8 of 22 (36%) had at least one fall in the past year. Participants had a mean gait speed of 0.8 m/s, a mean SPPB score of 8.9, and mean TUG time of 13.8 seconds. The sensitivity, specificity, and area under the curve (AUC) for the gait analyzer against the functional domains were 1.00, 0.84, and 0.92, respectively, for SPPB (balance and gait); 0.38, 0.89, and 0.64, respectively, for FRAIL-functional; 0.45, 0.91, and 0.68, respectively, for FROP-Com; 0.60, 1.00, and 0.80, respectively, for gait speed; and 1.00, 0.94, and 0.97, respectively, for TUG. The heart rate analyzer demonstrated superior validity for the nonfunctional components of frailty, with a sensitivity of 1.00, specificity of 0.73, and AUC of 0.83. Conclusions Agreement between the gait and heart rate analyzers and the functional components of the FRAIL scale, gait speed, and FROP-Com was significant. In addition, there was significant agreement between the heart rate analyzer and the nonfunctional components of the FRAIL scale. The gait and heart rate analyzers could be used in a screening test for frailty and falls in community-dwelling older adults but require further improvement and validation at the population level.
BACKGROUND Aging is a risk factor for falls, frailty, and disability. The utility of wearables to screen for physical performance and frailty at the population level is an emerging research area. To date, there is a limited number of devices that can measure frailty and physical performance simultaneously. OBJECTIVE The aim of this study is to evaluate the accuracy and validity of a continuous digital monitoring wearable device incorporating gait mechanics and heart rate recovery measurements for detecting frailty, poor physical performance, and falls risk in older adults at risk of falls. METHODS This is a substudy of 156 community-dwelling older adults ≥60 years old with falls or near falls in the past 12 months who were recruited for a fall prevention intervention study. Of the original participants, 22 participants agreed to wear wearables on their ankles. An interview questionnaire involving demographics, cognition, frailty (FRAIL), and physical function questions as well as the Falls Risk for Older People in the Community (FROP-Com) was administered. Physical performance comprised gait speed, timed up and go (TUG), and the Short Physical Performance Battery (SPPB) test. A gait analyzer was used to measure gait mechanics and steps (FRAIL-functional: fatigue, resistance, and aerobic), and a heart rate analyzer was used to measure heart rate recovery (FRAIL-nonfunctional: weight loss and chronic illness). RESULTS The participants’ mean age was 74.6 years. Of the 22 participants, 9 (41%) were robust, 10 (46%) were prefrail, and 3 (14%) were frail. In addition, 8 of 22 (36%) had at least one fall in the past year. Participants had a mean gait speed of 0.8 m/s, a mean SPPB score of 8.9, and mean TUG time of 13.8 seconds. The sensitivity, specificity, and area under the curve (AUC) for the gait analyzer against the functional domains were 1.00, 0.84, and 0.92, respectively, for SPPB (balance and gait); 0.38, 0.89, and 0.64, respectively, for FRAIL-functional; 0.45, 0.91, and 0.68, respectively, for FROP-Com; 0.60, 1.00, and 0.80, respectively, for gait speed; and 1.00, 0.94, and 0.97, respectively, for TUG. The heart rate analyzer demonstrated superior validity for the nonfunctional components of frailty, with a sensitivity of 1.00, specificity of 0.73, and AUC of 0.83. CONCLUSIONS Agreement between the gait and heart rate analyzers and the functional components of the FRAIL scale, gait speed, and FROP-Com was significant. In addition, there was significant agreement between the heart rate analyzer and the nonfunctional components of the FRAIL scale. The gait and heart rate analyzers could be used in a screening test for frailty and falls in community-dwelling older adults but require further improvement and validation at the population level.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.