2020 International Conference on Industry 4.0 Technology (I4Tech) 2020
DOI: 10.1109/i4tech48345.2020.9102640
|View full text |Cite
|
Sign up to set email alerts
|

FACTS Devices for Reactive Power Compensation and Power Flow Control – Recent Trends

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Figure 2. Schematic PI control method [3] The algorithm illustrates the steps of using PI control method in STATCOM to compensate the reactive power: -Step 1: measured voltage and current at PCC, furthermore the load current.…”
Section: Statcom In Power Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 2. Schematic PI control method [3] The algorithm illustrates the steps of using PI control method in STATCOM to compensate the reactive power: -Step 1: measured voltage and current at PCC, furthermore the load current.…”
Section: Statcom In Power Systemmentioning
confidence: 99%
“…It has the capability to both supply and absorb reactive power, thus preserving voltage stability in electrical power transmission and distribution systems [2]. Recently, FACTS devices have been used, where a STATCOM is used as a voltage source inverter (VSI) with a fix DC capacitor which acts as a substitute for a synchronous condenser, by providing the required VAR control by selecting a fixed set of capacitors, with fast voltage control and improved PF [3].…”
Section: Introductionmentioning
confidence: 99%
“…It is defined that P total will be maximum at unity power factor. So, at cos ; 1 ð Þ¼1, the final values of the a and b would be as a ¼ 2=3 and b ¼ ffiffiffiffiffiffiffi ffi 2=3 p and the total maximum power would be as Equation (18).…”
Section: Working Principle Of the Proposed Systemmentioning
confidence: 99%
“…FACTS in the power system is also a way to enhance the capacity and utilize the conductor near to their maximum limit. 18,19 However, it has been seen the economic efficiency is only remarkably reflected in the high voltage power transmission system, and at the distribution level, it shows very poor economic efficiency. 20 Moreover, with the development of distributed generation (DG) and DC loads, such as battery storage plant, solar photovoltaic, and electric vehicle charging station, the DC penetration in the power system is enhanced, especially in the distribution network.…”
Section: Introductionmentioning
confidence: 99%
“…The position of the UPFC is recommended to be on the line with the greatest chance of severity. UPFC is tuned for providing compensation [8]. The proposed method is implemented and tested on IEEE 14 and IEEE 118 bus system.…”
Section: Introductionmentioning
confidence: 99%