Faecal immunochemical testing (FIT): Sources of analytical variation based on three years of routine testing in the context of DG30

Abstract: words)Aims: To determine analytical capabilities of a commonly used faecal immunochemical test (FIT) to detect haemoglobin (Hb) in the context of NICE guidance DG30, and the likely use of FIT to reprioritise patients delayed by the COVID-19 pandemic.Methods: Data obtained from independent verification studies and clinical testing of the HM-JACKarc FIT method in routine primary care practice were analysed to derive analytical performance characteristics.Results: Detection capabilities for the FIT method were 0.… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
7
0

Year Published

2020
2020
2020
2020

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…It is possible that, as a consequence of the delay between collection and arrival in the laboratory, some degree of degradation may have occurred and the quantitative FIT value may represent an underestimation of the true haemoglobin concentration 30 . The excellent discriminatory value of FIT (AUC of 0.941) and the low number of false negatives reported in this large in‐context cohort indicates that haemoglobin degradation is not a major limitation of clinical performance when using a low threshold of FIT 29 …”
Section: Discussionmentioning
confidence: 84%
See 2 more Smart Citations
“…It is possible that, as a consequence of the delay between collection and arrival in the laboratory, some degree of degradation may have occurred and the quantitative FIT value may represent an underestimation of the true haemoglobin concentration 30 . The excellent discriminatory value of FIT (AUC of 0.941) and the low number of false negatives reported in this large in‐context cohort indicates that haemoglobin degradation is not a major limitation of clinical performance when using a low threshold of FIT 29 …”
Section: Discussionmentioning
confidence: 84%
“…Specimen preparation is a critical step in the overall performance of the FIT method 28,29 . The methodological approach used in the present study involved collection of faeces by the patient into a standard sample pot which was then sampled into the FIT collection device by trained staff in the laboratory.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Specimen preparation is a critical step in the overall performance of the FIT method (18,19). The methodological approach used in the present study involved collection of stool by the patient into a standard stool sample pot which was then sampled into the FIT method collection device by trained staff in the laboratory.…”
Section: Discussionmentioning
confidence: 99%
“…Our laboratory staff sampled 33 faecal specimens in triplicate. 8 About 31 (93.9%) specimens were consistently positive or negative around ≥10 µg Hb/g. The variability of FIT results (median coefficient of variation, 27.8%, range 20.5% to 48.6%) was reduced after specimens were homogenised (10.2%, 7.0% to 13.5%), and all specimens were consistently categorised.…”
mentioning
confidence: 95%