2019
DOI: 10.1016/j.ijrefrig.2018.11.028
|View full text |Cite
|
Sign up to set email alerts
|

Failure analysis of condensing units for refrigerators with refrigerant R134a, R404A

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
7
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 28 publications
1
7
0
2
Order By: Relevance
“…The worsened lubricating properties of compressor oil in the presence of refrigerant are compatible with general expectations [ 4 , 18 , 19 , 21 , 24 ]. Such a trend under starved (or submerged) lubrication conditions was found for the R404A/POE [ 3 , 26 , 49 ] and for R600a/MO mixtures [ 13 , 20 , 28 ]. The reason for the deterioration of lubricating properties is the formation of the refrigerant–oil mixture which has a lower viscosity than oil.…”
Section: Discussionsupporting
confidence: 53%
See 1 more Smart Citation
“…The worsened lubricating properties of compressor oil in the presence of refrigerant are compatible with general expectations [ 4 , 18 , 19 , 21 , 24 ]. Such a trend under starved (or submerged) lubrication conditions was found for the R404A/POE [ 3 , 26 , 49 ] and for R600a/MO mixtures [ 13 , 20 , 28 ]. The reason for the deterioration of lubricating properties is the formation of the refrigerant–oil mixture which has a lower viscosity than oil.…”
Section: Discussionsupporting
confidence: 53%
“…Previous articles [ 3 , 4 ] prove that damage to refrigeration compressors is largely caused mechanically, mainly because of inefficient lubrication, i.e., lack of oil, its solution with refrigerant and insufficient quantity of oil.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, the traditional FMEA has been widely used in numerous fields including manufacturing [31,32], marine [33,34], aerospace [35,36], healthcare [37][38][39] and electronics [40][41][42]. The application of crisp values in the traditional FMEA has been strongly criticized by researchers [43][44][45].…”
Section: Fuzzy Fmea (Phase 2)mentioning
confidence: 99%
“…The study suggested R290 as a substitute to R22 because R290 has a low impact on the environment and * To whom correspondence should be addressed excellent thermodynamic performance. Other studies have investigated tetrafluoroethane (R134a) and compared it with different refrigerants [9][10][11] and [12]. Vapour compression refrigeration systems can be used to provide a low temperature for a short time by using refrigerants that have positive effects on the environment [13][14][15] and [16].…”
Section: Introductionmentioning
confidence: 99%