Failure investigation of an elbow pipe used in sewage water treatment facility
Siddharth Garg,
Sourabh Bansal,
Qasim Murtaza
Abstract:In this research work, a real case of failed ASTM A860 WPHY 65 long elbow pipe coated with inorganic zinc ethyl silicate primer is collected from a treatment facility to investigate the root causes of its failure, which was reported after approximately 28 months of use. The failure was investigated using visual observations, metallurgical analysis using optical emission spectroscopy, mechanical testing, X‐ray diffraction of corrosion product, chemical analysis of sewage and corrosion rate test of the elbow usi… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.