Handbook of Vibrational Spectroscopy 2001
DOI: 10.1002/0470027320.s0219
|View full text |Cite
|
Sign up to set email alerts
|

Fast and Ultrafast Time‐Resolved Mid‐Infrared Spectrometry Using Lasers

Abstract: The sections in this article are Introduction Fast TRIR Spectroscopy Fast TRIR Spectroscopy Using IR Lasers CW CO Lasers … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 139 publications
0
6
0
Order By: Relevance
“…sampling more than 100 cm −1 at once) and multi-channel detection. In parallel, signal-to-noise ratio has been improved by higher photon flux lasers and superior time resolution has been made possible by shorter laser pulse times (Grills & George 2002). In addition to studies of CO photolysis from proteins, lighttriggered time-resolved IR methods have been applied to a range of small-molecule systems including transition metal carbonyl complexes (Butler et al 2007) and photodamaged DNA bases (Kuimova et al 2006).…”
Section: Recent Developments In Infrared Instrumentation and Methodolmentioning
confidence: 99%
“…sampling more than 100 cm −1 at once) and multi-channel detection. In parallel, signal-to-noise ratio has been improved by higher photon flux lasers and superior time resolution has been made possible by shorter laser pulse times (Grills & George 2002). In addition to studies of CO photolysis from proteins, lighttriggered time-resolved IR methods have been applied to a range of small-molecule systems including transition metal carbonyl complexes (Butler et al 2007) and photodamaged DNA bases (Kuimova et al 2006).…”
Section: Recent Developments In Infrared Instrumentation and Methodolmentioning
confidence: 99%
“…23 However, such a source does not provide sufficient intensity in the mid-IR portion of the spectrum. Traditionally, continuous wave (CW) mid-IR sources for nano-to millisecond TRIR spectroscopy have been limited to either globars 26,27 and tunable lead-salt diode lasers, 28 both of which require the use of a monochromator to select a single probe wavelength, or line-tunable CO or CO 2 gas lasers 28,29 (see Table I for a list of the advantages and disadvantages of these sources for use with pulse radiolysis). Each of these has proved to be extremely useful in different forms of TRIR spectroscopy when coupled with laser flash photolysis.…”
Section: B Quantum Cascade Lasers As An Ir Probe Sourcementioning
confidence: 99%
“…However, absorption bands in these regions (particularly in the UV and visible) are often broad and difficult to assign to specific structures of reaction intermediates that would aid in mechanistic interpretation. Time-resolved vibrational spectroscopy (TRVS), with either mid-IR absorption or resonance Raman detection, [6][7][8] is a particularly powerful approach since in contrast to the majority of UV/visible measurements, it can provide rich structural information on transient species through the appearance of narrow, highly characteristic spectral bands. Thus, time-resolved infrared (TRIR) and time-resolved resonance Raman (TR 3 ) spectroscopy have become widely used techniques for the identification of short-lived intermediates generated by pulsed laser excitation.…”
Section: Introductionmentioning
confidence: 99%