2006
DOI: 10.1002/jssc.200600102
|View full text |Cite
|
Sign up to set email alerts
|

Fast chiral separation by ligand‐exchange HPLC using a dynamically coated monolithic column

Abstract: The preparation and application of dynamically coated ligand-exchange chromatography phases for enantioseparation is described. The phases were prepared by pumping a solution of N-decyl-L-4-hydroxyproline, N-hexadecyl-L-4-hydroxyproline, or N-2-hydroxydodecyl-L-4-hydroxyproline through a commercially available monolithic RP-18 column. These coatings are stable against desorption for months at ambient temperature when aqueous mobile phases are used. The columns were applied to the chiral separation of amino aci… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 40 publications
(23 citation statements)
references
References 12 publications
1
22
0
Order By: Relevance
“…Schmid et al. also reported stereoseparations a series of dipeptides on dynamically coated ligand‐exchange columns. Such level of stereoselectivities allowed a partial resolution of four stereoisomers of dipeptides .…”
Section: Chiral Separation Of Small Peptidesmentioning
confidence: 99%
“…Schmid et al. also reported stereoseparations a series of dipeptides on dynamically coated ligand‐exchange columns. Such level of stereoselectivities allowed a partial resolution of four stereoisomers of dipeptides .…”
Section: Chiral Separation Of Small Peptidesmentioning
confidence: 99%
“…This technique is usually employed in three separate forms: (i) in the "chiral-bonded ligand exchanging stationary phases" the chiral selector is covalently attached to the stationary phase [68]; (ii) ligand-exchange columns are prepared by dynamically coating the commercially available reversed-phase columns with a hydrophobic chiral selector [69,70] and (iii) the chiral selector predominantly resides in the mobile phase, in this case, the selector complex is continuously introduced into the column. Analytes to be resolved form the mixed-ligand complexes with the selector, which are diastereomeric in their structure.…”
Section: Copper (Ii) Amino Acid Complexes As Reagents In Lecmentioning
confidence: 99%
“…Schmid et al. had suggested dynamically coated monolithic ligand‐exchange columns to speed up analysis. However, this approach had not been applied yet for the determination of chiral quinolones.…”
Section: Chiral Resolution By Hplcmentioning
confidence: 99%