1993
DOI: 10.1016/0584-8547(93)80154-m
|View full text |Cite
|
Sign up to set email alerts
|

Fast, low-level detection of strontium-90 and strontium-89 in environmental samples by collinear resonance ionization spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
0

Year Published

1993
1993
2017
2017

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 42 publications
(24 citation statements)
references
References 10 publications
1
23
0
Order By: Relevance
“…Hence, in addition to the intrinsic interest for understanding complex fine-hyperfine interactions, the need to predict the hyperfine structure for 89Sr has been a motivation for this work. Details of the experimental apparatus have been described elsewhere [9] and are only briefly reviewed here. Aqueous samples of Sr (NO3)2, dried and atomized in a graphite tube furnace, are surface ionized by passing through a tantalum tube, which is resistively heated to 2300 °C and is lined with rhenium foil to increase ionization efficiency.…”
Section: Methodsmentioning
confidence: 99%
“…Hence, in addition to the intrinsic interest for understanding complex fine-hyperfine interactions, the need to predict the hyperfine structure for 89Sr has been a motivation for this work. Details of the experimental apparatus have been described elsewhere [9] and are only briefly reviewed here. Aqueous samples of Sr (NO3)2, dried and atomized in a graphite tube furnace, are surface ionized by passing through a tantalum tube, which is resistively heated to 2300 °C and is lined with rhenium foil to increase ionization efficiency.…”
Section: Methodsmentioning
confidence: 99%
“…24), which is installed in close proximity to the labs employed for the chemical separation procedure. RISIKO is a 30 kV high transmission mass separator that has been set up specifically for elemental ultra-trace determination using resonance ionization mass spectrometric (RIMS) techniques with lasers [115]. As one of the leading development facilities for on-line laser ion sources worldwide, it is equipped with a number of tunable solid-state laser systems for resonance ionization.…”
Section: Mass Separationmentioning
confidence: 99%
“…These demands can be met by RIS on a fast atomic beam in collinear geometry by use of cw laser light for excitation [8]. Figure 4 shows the set-up.…”
Section: Resonance Ionization Spectroscopy On a Fast Aomic Beam In Comentioning
confidence: 99%