2009
DOI: 10.1007/s00216-009-2708-x
|View full text |Cite
|
Sign up to set email alerts
|

Fast preparation of polystyrene-based monolith using microwave irradiation for micro-column separation

Abstract: The conventional analytical HPLC was successfully developed for micro-column separation by using a simple eluate splitting system, a self-preparation of monolithic column and an on-capillary column detector in our laboratory. A typical polystyrene-based monolith was quickly prepared inside the fused-silica capillary, which in situ polymerization was carried out in 10 min by microwave irradiation. The reactant solution consisted of styrene (ST) as a functional monomer, divinylbenzene (DVB) as a cross-linking ag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0
2

Year Published

2011
2011
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 32 publications
0
5
0
2
Order By: Relevance
“…Dari hasil percobaan ini dapat diketahui bahwa monolith III merupakan monolith dengan komposisi terbaik untuk dapat diaplikasikan dalam pemisahan molekul alkilbenzena berukuran kecil, dengan nilai N mencapai 17260 plate/m kolom. Nilai N pada monolith ini lebih besar daripada monolith serupa yang dikembangkan oleh Zhang et al [8] …”
Section: Porositas Dan Distribusi Pori Monolithunclassified
See 1 more Smart Citation
“…Dari hasil percobaan ini dapat diketahui bahwa monolith III merupakan monolith dengan komposisi terbaik untuk dapat diaplikasikan dalam pemisahan molekul alkilbenzena berukuran kecil, dengan nilai N mencapai 17260 plate/m kolom. Nilai N pada monolith ini lebih besar daripada monolith serupa yang dikembangkan oleh Zhang et al [8] …”
Section: Porositas Dan Distribusi Pori Monolithunclassified
“…Penggunaan porositas dan ukuran pori yang dapat divariasi, monolith terbukti dapat berfungsi sebagai media pemisahan dalam kromatografi untuk pemisahan berbagai analit, mulai dari molekul berukuran kecil [3,[7][8], hingga makromolekul seperti peptida dan protein [9][10], dan juga oligodeoxythymidylic acids [2].…”
unclassified
“…The higher amount of hydrophilic monomer HEMA in the monomer composition reduced hydrodynamic permeability of the resulting monolithic stationary phases and improved column efficiency in separating small molecules. Another approach, addition of methacrylic acid (MAA) into either the polystyrene-based monoliths for reversed-phase capillary LC analysis or the EDMA-based monoliths for hydrophilic interaction chromatography (HILIC), was also performed by various research groups in order to increase hydrophilic interactions between analytes and monolithic stationary phases [31][32][33][34]. By adding MAA, Svobodová et al [32] successfully synthesized a poly(styrene-DVB-MAA) monolithic column (320-mm i.d., 17-cm long) for capillary LC analysis of small molecules.…”
Section: Introductionmentioning
confidence: 99%
“…Compared with inorganic silica-based adsorbents, polymeric materials have some intrinsic advantages. For example, their use with liquids within the entire range of pH is possible [21,22]. In this paper, a divinylbenzene polymer (DVB)/Fe 3 O 4 hybrid monolithic column was prepared for the preconcentration of MeHg in sample solution, which had not been indicated in other publications.…”
Section: Introductionmentioning
confidence: 99%