2010
DOI: 10.1365/s10337-010-1756-x
|View full text |Cite
|
Sign up to set email alerts
|

Fast Speciation of Iodide and Iodate in Edible Salts and Human Urine by Short Column IC Coupled with Inductively Coupled Plasma MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
10
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 19 publications
1
10
1
Order By: Relevance
“…For iodide, iodate, MIT, and DIT, the respective LODs were 2.64, 0.76, 0.78, and 0.50 ng/g and the corresponding LOQs were 6.29, 3.21, 1.10, and 0.72 ng/g. In comparison with previous studies employing an anion exchange column, the LOD and LOQ obtained herein were far lower (Romarís‐Hortas et al., ; Romarís‐Hortas et al., ; Zhang et al., ). The accuracy of the method was verified by employing a CRM.…”
Section: Resultscontrasting
confidence: 73%
See 1 more Smart Citation
“…For iodide, iodate, MIT, and DIT, the respective LODs were 2.64, 0.76, 0.78, and 0.50 ng/g and the corresponding LOQs were 6.29, 3.21, 1.10, and 0.72 ng/g. In comparison with previous studies employing an anion exchange column, the LOD and LOQ obtained herein were far lower (Romarís‐Hortas et al., ; Romarís‐Hortas et al., ; Zhang et al., ). The accuracy of the method was verified by employing a CRM.…”
Section: Resultscontrasting
confidence: 73%
“…To separate iodine using anion exchange HPLC‐ICP‐MS, certain mobile phases were screened in a prior study (Han et al., ; Romarís‐Hortas et al., ; Romarís‐Hortas et al., ; Zhang et al., ). Given that ammonium nitrate (NH 4 NO 3 ) dissolved in ultrapure water exhibited the most powerful elution power without overlap of the peaks, it was selected as the mobile phase.…”
Section: Resultsmentioning
confidence: 99%
“…The instruments, reagents used in this study and the optimal instrumental operating parameters were all same as that of our previous work 17,18 and the contents of total iodine and speciation of iodine were determined according to the references 17,18 via inductively plasma mass spectrometry (ICP-MS) and short column ion chromatography coupled with inductively plasma mass spectrometry (IC-ICP-MS) which proposed by ourselves, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…In the past, iodine concentration or speciation has been measured in natural and drinking water (Chen et al, 2007;Liu et al, 2015;Wang and Jiang, 2008;Wei et al, 2007), precipitation (Gilfedder et al, 2007a;Yoshida et al, 2007), soil (Yoshida et al, 2007), animal and microalgae tissues (Hughes et al, 2006;Kaňa et al, 2015;Shah et al, 2005), edible salts (Yun et al, 2017;Zhang et al, 2010), and milk (Wang and Jiang, 2008). Previous measurements in ambient aerosols showed only three iodine species: I -, iodate (IO 3 -) and total soluble organic iodine (SOI) and their relative concentration and size distribution varied largely with locations (e.g.…”
Section: Introductionmentioning
confidence: 99%