2017
DOI: 10.1016/j.ijfatigue.2016.09.011
|View full text |Cite
|
Sign up to set email alerts
|

Fatigue crack propagation analysis for multiple weld toe cracks in cut-out fatigue test specimens from a girth welded pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 27 publications
(13 citation statements)
references
References 25 publications
0
13
0
Order By: Relevance
“…The Elastic Modulus of 210 GPa and a Poisson's ratio of 0.3 for the steel material was used. The model is for a four-point bend fatigue specimens reported by Pang et al [10]. The dimensions of the steel plate are shown in Table 2.…”
Section: Modelling Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…The Elastic Modulus of 210 GPa and a Poisson's ratio of 0.3 for the steel material was used. The model is for a four-point bend fatigue specimens reported by Pang et al [10]. The dimensions of the steel plate are shown in Table 2.…”
Section: Modelling Proceduresmentioning
confidence: 99%
“…For the fatigue life prediction, the material was modeled following X65 steel, similar to a previous experiment [10]. The yield strength and ultimate tensile strength of the base material was obtained via relation to hardness (σ Y = 550 and UTS = 633 MPa).…”
Section: Fatigue Life Predictionmentioning
confidence: 99%
See 1 more Smart Citation
“…Welded X65 offshore pipes with an outer diameter of 32" and 1" wall thickness were cut into fatigue coupons and tested in four-point bending (Pang et al, 2017). Tensile stresses occur at pipe outer surface of the weld cap.…”
Section: Arc-welded and Laser Welded Jointsmentioning
confidence: 99%
“…In prior testing [1], butt-welded X65 offshore pipes (outer diameter 32" and 1" thickness) were cut into fatigue coupons (t= 25.4 mm, b= 100 mm). A four-point bending test (L= 240 mm, l= 120 mm) was setup ( Fig.…”
Section: Introductionmentioning
confidence: 99%