Abstract:Gear is a reliable part of power transmission. This article presents a metallurgical failure analysis of a failed gear used in automobile engine coolant pumps. In gear, the soft microstructure of pearlite and ferrite is witnessed in metallographic analysis. Significant wear is perceived in gear teeth, and significant deformation is observed in the keyway. The crack initiated from the corner radius of the keyway and propagated towards to the root of the teeth, which is evidence of the failure due to fatigue. Re… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.