All Days 1980
DOI: 10.4043/3696-ms
|View full text |Cite
|
Sign up to set email alerts
|

Fatigue Strength Of Tubular T- And X-Joints

Abstract: The results of fatigue tests on 40 tubular T and X-joints are presented. The chord diameters of the joints are 168, 457 and 914 mm. The most important conclusions are that the lifetime decreases with increasing joint size and that in the high cycle rance (N ? 107) some test results of the large joints fall below the AWS-X curve. INTRODUCTION The weather conditions which induce a fatigue crack are more severe in the North Sea than in the Gu1f of Mexic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

1984
1984
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…There is a limited amount of published data on the SCFs of DT tubular joints, which can be compared to Efthymiou and Wordsworth and Smedley parametric equations. However, some published data collected from the literature [ 16 , 17 , 18 , 19 ] are included in this comparison.…”
Section: Design Stress Concentration Factor (Scf)mentioning
confidence: 99%
See 1 more Smart Citation
“…There is a limited amount of published data on the SCFs of DT tubular joints, which can be compared to Efthymiou and Wordsworth and Smedley parametric equations. However, some published data collected from the literature [ 16 , 17 , 18 , 19 ] are included in this comparison.…”
Section: Design Stress Concentration Factor (Scf)mentioning
confidence: 99%
“…These methods include: Present experimental work. Previous experimental work [ 16 , 17 , 18 , 19 ]. Range of valid finite element analyses.…”
Section: Scfs Comparisonmentioning
confidence: 99%
“…This section demonstrates the reliability of the proposed ENS extrapolation in assessing the fatigue life of 23 CHS X-joint specimens extracted from the literature, [32][33][34] all tested under the constant-amplitude load in a laboratory air environment. The selected specimens consist of isolated X-joints in an as-welded condition subjected to either brace axial tension or brace in-plane bending.…”
Section: F a T I G U E A S S E S S M E N T U S I N G T H E P R O P O mentioning
confidence: 99%
“…Approach. Initially, fatigue assessment of welded joints based on Hot Spot stress approach was used for welded joints of tube elements[68]. Later, it began to be used…”
mentioning
confidence: 99%